Extending the cooling downtime
The cooling down phase which takes
place before the end of a programme
can be extended by 5 or 10 minutes,
if required. This makes the garments
easier to handle.
The cooling down time can only be
extended for programmes with drying
levels.
Follow the steps (A,B,C...) to
programme and store in memory.
Before you begin, ensure that:
The tumble dryer is switched off.
The door is closed.
APress the Start/Stop button and keep
it pressed in whilst carrying out steps
B-C.
BSwitch the dryer on.
Wait until the Start/Stop button lights up
constantly ...
C. . . and then release the Start/Stop
button.
DPress the Low temperature button
five times.
The Low temperature indicator light
will flash seven times briefly.
Anumber to show which option is
selected will appear in the display
alternating with the letter P.
0Cooling down time not extended
(factory default setting)
iCooling down time extended by
five minutes
(the Automatic plus indicator light will
also flash once).
2Cooling down time extended by
ten minutes
(the Automatic plus indicator light will
also flash twice).
EPressing the Start/Stop button
switches between the options.
FSwitch the dryer off.
The setting you have selected is now
stored in memory. You can change it
again at any time.
To check the setting:
^Carry out steps Ato D.
^Switch the dryer off after step D.
Programmable functions
55