Troubleshooting
Once the flow of water ceases:
Pull the drain filter entirely out.
Thoroughly clean the filter.
Turn the pump blade by hand to check that it moves freely, and remove any foreign objects (buttons, coins, etc.) that are causing an obstruction.
Put the drain filter back in place and tighten it down.
If the drain filter is not securely tightened, there is a risk of water leakage during operation.
Opening the loading door
NEVER reach into the drum until is has completely stopped moving. Reaching into a moving drum carries the risk of serious injury.
Pull the emergency release (see illustration). The loading door will open.
40