Milan Technology E-FL-HB-0400 FAULT ISOLATION and CORRECTION, Install E-FL-HB-0x00 at Site

Models: E-FL-HB-0400 EFLHB0X00

1 8
Download 8 pages 143 b
Page 5
Image 5
FAULT ISOLATION and CORRECTION

FAULT ISOLATION and CORRECTION

If the E-FL-HB-0x00 fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action:

1.Is the P(o)W(e)R LED on the E-FL-HB-0x00 illuminated?

NO

Is the power cord properly installed in the E-FL-HB-0x00 and in the grounded AC outlet?

Does the grounded AC outlet provide power?

Contact Technical Support: (800) 260-1312.

YES

Continue at step 2.

2.Is a backbone uplink adapter installed at E-FL-HB-0x00 back?

NO

Continue at step 7.

YES

Continue at step 3.

3.Is the B(ack)B(one) STAT(us) LED illuminated continuously?

YES

Continue at step 7.

NO

Continue at step 4.

4.Does the B(ack)B(one) STAT(us) LED continuously blink ONCE?

YES

Ensure that backbone uplink adapter is firmly connected.

Check backbone uplink cables for proper cabling and connection(s).

Ensure that device at remote end of network link is powered.

Contact Technical Support: (800) 260-1312.

NO

Continue at step 5.

5.Does the B(ack)B(one) STAT(us) LED continuously blink TWICE? YES

If the AUI backbone adapter plate is installed, check the installed transceiver or the drop cable connections.

If the BNC backbone adapter plate is installed, ensure that coaxial cable connections are secure and that daisy-chained cable is terminated at both ends. (See page 7.)

If the fiber backbone adapter plate is installed and LINKAlert™ is NOT enabled, the port is partitioned; investigate the device at the far end of the link..

If the fiber backbone adapter plate is installed and LINKAlert™ IS enabled, determine and correct the cause of the Far End Fault.

Contact Technical Support: (800) 260-1312.

NO

Install E-FL-HB-0x00 at Site

WARNING: During the site installation, handle the E-FL-HB-0x00 in such a way that the E-FL-HB-0x00 does not fall. Failure to observe this warning could result in injury to personnel and/or equipment damage.

NOTE: If E-FL-HB-0x00 is shipped with brackets installed, proceed to step 2.

To install the E-FL-HB-0x00 in 19-inch rack cabinet:

2

Install E-FL-HB-0x00 at Site 1

10BASE-FL

1

2

3

4

5

6

7

8

3

1.Remove and retain two (2) screws located at front left side and front right side of E-FL-HB-0x00 chassis. Install right and left front brackets (provided) on chassis by installing two (2) retained screws through each bracket into chassis.

2.Carefully align E-FL-HB-0x00 between 19-inch rack mounting rails.

3.Install E-FL-HB-0x00 by installing two (2) screws through right front bracket into rack and two (2) screws through left front bracket into rack, using clip nuts (NOT provided) to secure, if necessary.

To install the E-FL-HB-0x00 on table or other flat surface:

NOTE: Rubber feet are provided.

1.Carefully turn E-FL-HB-0x00 to side.

2. Install four (4) rubber feet:

Separate rubber feet.

Remove protective paper

from adhesive surface on rubber foot.

• Position and secure each rubber foot as shown.

3.Return E-FL-HB-0x00 to upright position.

Continue at step 6.

Page 5
Image 5
Milan Technology E-FL-HB-0400, EFLHB0X00 specifications FAULT ISOLATION and CORRECTION, Install E-FL-HB-0x00 at Site