Optionally Connect to Backplane (continued)

THROUGH FIBER UPLINK

To connect fiber cable from E-FX-HB-xx00 10BASE-FL uplink adapter to network:

1.Locate 10BASE-FL uplink adapter installed at E-FL-HB-0x00 back. (See page 4.)

2.Locate or build 10BASE-FL compliant fiber cable with male two- stranded TX to RX connectors at both ends. (See page 14.)

TX

TX

TX

RX

RX

RX

RX

TX

3.Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors, respectively, on E-FL-HB-0x00 10BASE-FL uplink adapter.

4.Connect male TX and RX cable connectors at other end of cable to RX and TX connectors, respectively, on 802.3 compliant 10BASE-FL network device.

5.Set SWITCH 1 (located on the 10BASE-FL uplink adapter) to enable or to disable the LinkALERT™ function.

SWITCH

(UP) Enables the LinkALERTfunction. (DOWN)

1

2

 

Enables standard Link Integrity Test. Default is

 

 

 

 

 

 

 

 

 

 

LinkALERTenabled (UP).

 

 

 

 

 

NOTE: SWITCH 2 is not used.

 

 

 

 

 

 

 

 

 

 

NOTE: The LinkAlertfeature allows each port to pass network link faults over the port link. If the port does not detect a good link on one side, the port disables all transmission (including active-idle) on the other side.

 

LINK FAULT INDICATION

 

10BASE-FL

E-FL-HB-0x00

10BASE-FL

Device

Port

Device

LINK FAULT INDICATION

Optionally Cascade E-FL-0x00 Hubs

To cascade hubs by installing fiber cables between hubs:

10BASE-FL

1

2

3

4

5

6

7

8

10BASE-FL

1

2

3

4

5

6

7

8

1.Locate or build 10BASE-FL compliant two-stranded fiber cable with appropriate male TX to RX connectors installed at both ends.

TX

TX

TX

RX

RX

RX

RX

TX

2.Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors, respectively, on front of one hub.

3.Connect male TX and RX cable connectors at other end of cable to RX and TX connectors, respectively, on front of second hub.

Connect E-FL-0x00 Hub to Terminal Devices using Fiber

To connect fiber cable from E-FL-HB-0x00 ports to terminal devices:

10BASE-FL

1

2

3

4

5

6

7

8

1.Locate or build 10BASE-FL compliant two-stranded fiber cable with appropriate male TX to RX connectors installed at both ends.

TX

TX

TX

RX

RX

RX

RX

TX

2.Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors, respectively, on E-FL-HB-0x00 port.

3.Connect male TX and RX cable connectors at other end of cable to RX and TX connectors, respectively, on 802.3 compliant fiber device.

4.Repeat steps 1-3 until all terminal devices are connected.

Page 8
Image 8
Milan Technology EFLHB0X00 Optionally Cascade E-FL-0x00 Hubs, Connect E-FL-0x00 Hub to Terminal Devices using Fiber