Miller Electric Blue Star 145, 145 DXR, 145 manual Routine Maintenance

Models: 145 DXR, 145 Blue Star 145

1 54
Download 54 pages 11.08 Kb
Page 29
Image 29

. Complete Parts List available at www.MillerWelds.com

SECTION 8 − MAINTENANCE

.Follow the storage procedure in the engine owner’s manual if the unit will not be used for an extended period.

8-1. Routine Maintenance

! Stop engine before maintaining.

Recycle engine . See Engine Manual and Maintenance Label

fluids. for important start-up, service, and storage information. Service engine more often if used in severe conditions.

n = Check

Z = Change

~ = Clean

l = Replace

Reference

* To be done by Factory Authorized Service Agent

 

 

Every

 

 

Section 5-3,

8

 

 

5-4

Hours

 

 

 

n Fuel Level

n Oil Level

~ Oil, Fuel Spills

 

Every

 

 

Section 8-2

25

 

 

 

Hours

 

 

 

~ Air Cleaner Precleaner

 

 

 

Every

 

 

 

50

 

 

 

Hours

 

 

 

~ Weld Terminals

 

 

 

Every

 

 

Engine

100

 

 

Manual,

Hours

 

 

Section 8-2

Z Oil

nl Air Cleaner Element

~ Cooling System

n Spark Plug Gap

~ Battery Terminals (DX

n~ Spark Arrestor Screen

 

 

Models)

(Optional on DX Models)

 

 

Every

 

 

 

200

 

 

 

Hours

 

 

 

l Unreadable Labels

 

 

 

Every

 

 

Engine

300

 

 

Manual

Hours

 

 

 

nValve Clearance*

 

 

 

Every

 

 

Engine

500

 

 

Manual

Hours

 

 

 

nl Weld Cables

n~ Slip Rings*

 

 

 

nl Brushes*

 

 

 

 

 

OM-4417 Page 25