4-4. Volt-Ampere Curves For CC/CV Models

A.Stick Mode 100

 

 

RANGES:

 

80

MAX

 

155 − 450

 

 

115 − 320

 

 

75 − 195

VOLTS

60

40 − 90

40

 

DC

 

 

 

20

 

 

0

 

 

0

100

200

300

400

500

600

700

800

900

1000

 

 

 

 

 

DC AMPERES

 

 

 

 

 

B. MIG Mode

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

VOLTSDC

 

 

 

MAX

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

0

100

200

300

400

500

600

700

800

900

1000

 

 

 

 

 

DC AMPERES

 

 

 

 

 

C. TIG Mode

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RANGES:

 

 

 

80

 

 

 

 

 

 

60 − 365

 

 

 

 

 

 

 

 

 

35 − 250

 

 

 

 

 

 

 

 

 

 

25 − 155

 

 

VOLTSDC

40

 

 

 

 

 

 

15 − 75

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

20

0

0

100

200

300

400

500

 

 

DC AMPERES

 

 

The volt-ampere curves show the minimum and maximum voltage and amperage output capabilities of the welding generator. Curves of all other settings fall between the curves shown.

215 080-A / 215 083-A / 215 079-A

OM-4421 Page 17

Page 23
Image 23
Miller Electric 400P, 500 X manual Volt-Ampere Curves For CC/CV Models, Stick Mode, MIG Mode, TIG Mode, 155