4-8. Weld Output Terminals And Selecting Cable Sizes

 

 

 

 

Total Cable (Copper) Length In Weld Circuit Not Exceeding

 

 

 

 

100 ft (30 m) Or Less

150 ft

200 ft

250 ft

300 ft

350 ft

400 ft

 

 

 

(45 m)

(60 m)

(70 m)

(90 m)

(105 m)

(120 m)

 

 

 

 

 

YTurn Off power before

Welding

10 − 60%

60 − 100%

 

 

 

 

 

 

connecting to weld output

Duty

 

 

10 − 100% Duty Cycle

 

 

Amperes

Duty Cycle

 

 

 

 

terminals

 

Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

4

4

4

3

2

1

1/0

1/0

 

 

150

3

3

2

1

1/0

2/0

3/0

3/0

 

 

200

3

2

1

1/0

2/0

3/0

4/0

4/0

 

 

250

2

1

1/0

2/0

3/0

4/0

2-2/0

2-2/0

 

 

300

1

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

 

 

350

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

2-4/0

Electrode

Work

400

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

2-4/0

 

 

 

 

 

 

 

 

 

 

 

500

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-3/0

 

 

600

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

3-4/0

 

 

700

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

3-4/0

4-4/0

 

 

800

4/0

2-2/0

2-3/0

2-4/0

3-4/0

3-4/0

4-4/0

4-4/0

Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

S-0007-D

4-9. Connecting Weld Output Cables

4

 

1

 

 

 

 

 

Do not place

 

 

 

anything between

 

 

 

weld cable terminal

 

 

 

and copper bar.

 

2

 

 

Tools Needed:

3

 

 

 

 

 

3/4 in (19 mm)

 

 

 

 

 

Correct Installation

Y Turn off power before connecting to

1

Weld Output Terminal

weld output terminals.

 

2

Supplied Weld Output Terminal Nut

 

 

Y Failure to properly connect weld

3

Weld Cable Terminal

cables may cause excessive heat

4

Copper Bar

and start a fire, or damage your ma-

Remove supplied nut from weld output ter-

chine.

 

803 778-B

Incorrect Installation

minal. Slide weld cable terminal onto weld output terminal and secure with nut so that weld cable terminal is tight against copper bar. Do not place anything between weld cable terminal and copper bar. Make

sure that the surfaces of the weld cable terminal and copper bar are clean.

OM-222 Page 18

Page 22
Image 22
Miller Electric 852 manual Weld Output Terminals And Selecting Cable Sizes, Connecting Weld Output Cables