7-4. Remote Voltage/Amperage Control On CC/CV Models (Optional)

1 Remote 14 Receptacle RC14

Connect optional remote control to

RC14 (see Section 5-11).

1

Example: Combination Remote Amperage Control (Stick)

In Example:

Process = Stick (Using Remote On/Off)

 

 

Range = 110 to 315 A DC

 

Min = 110 A DC

 

Max = 315 A DC

 

 

 

 

Max (315 A DC)

 

 

 

 

Min (110 A DC)

Set V/A

Set Remote

Set Range

Control Not

Adjust Optional Remote Control

Adjust Switch

Process

 

Used In Remote

 

 

 

 

 

Stick Mode

Example: Combination Remote Amperage Control (TIG)

Set V/A

 

Set Remote

 

Set Range

 

 

Adjust Switch

 

Process

 

 

 

 

In Example:

Process = TIG (Using Remote On/Off)

Range = 40 to 240 A DC

Percentage Of Range = 50%

Min = 40 A DC

Max = About 140 A DC (50% of 40 to 240)

Max (140 A DC)

Min (40 A DC)

Set Control

 

Adjust Optional Remote Control

 

 