Miller Electric Big Blue 452P manual Operating Auxiliary Equipment, Volt And 240 Volt Receptacles

Models: Big Blue 452P Big Blue 302P

1 96
Download 96 pages 21.62 Kb
Page 44
Image 44

SECTION 8 − OPERATING AUXILIARY EQUIPMENT

8-1. 120 Volt And 240 Volt Receptacles

3

4

1 120 V 20 A AC GFCI

Receptacle GFCI1

2 240 V 30 A AC Twistlock

Receptacle RC1

Receptacles supply 60 Hz single- phase power at weld/power speed.

 

 

 

If a ground fault is detected, GFCI

1

2

Reset button

pops

out

and

receptacle does not work. Check

 

 

 

 

 

 

for faulty tools plugged in

 

 

 

receptacle. Press button to reset

 

 

 

GFCI1.

 

 

 

 

 

 

. At least once a month, run en-

 

 

 

 

gine at weld/power speed and

 

 

 

 

press test button to verify GFCI

 

 

 

 

is working properly.

 

 

 

 

 

3

Circuit Breaker CB1

 

 

 

 

4

Circuit Breaker CB2

 

 

 

 

CB1 protects RC1 and the genera-

 

 

 

tor winding from overload. If CB1

 

 

 

opens, RC1 and GFCI1 do not

 

 

 

work. Place switch in On position to

 

 

 

reset breaker.

 

 

 

 

 

 

CB2 protects GFCI1 from overload.

 

 

 

 

 

 

If CB2 opens, GFCI1 does not

 

 

 

work. Press button to reset breaker.

 

 

 

. If a circuit breaker continues to

 

 

 

 

open, contact Factory Autho-

 

 

 

 

rized Service Agent.

 

 

 

 

. Generator

power

is not

af-

 

 

 

 

fected by weld output.

 

Maximum output is 2.4 kVA/kW from GFCI1 and 4 kVA/kW from RC1. Maximum output from all re- ceptacles is 4 kVA/kW.

EXAMPLE: If 13 A is drawn from RC1, only 7 A is available at GFCI1:

(240 V x 13 A) + (120 V x 7 A) = 4.0 kVA/kW

191 624-A

OM-496 Page 38

Return To Table Of Contents

Page 44
Image 44
Miller Electric Big Blue 452P Operating Auxiliary Equipment, Volt And 240 Volt Receptacles, At least once a month, run en