OM-496 Page 17Return To Table Of Contents

4-4. Volt-Ampere Curves For CC/CV Models

202 655 / 202 656 / 202 654
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of a l l
other settings fall between the
curves shown.
A. Stick Mode
B. MIG Mode
C. TIG Mode
0
20
40
60
80
100
0 100 200 300 400 500 600 700 800 900
DC AMPERES
DC VOLTS
Ranges
Max
150 − 420
110 − 315
75 − 200
40 − 90
0
20
40
60
80
100
0 100 200 300 400 500 600 700 800 900 1000
MAX
MIN
0
10
20
30
40
50
60
70
80
90
100
0 50 100 150 200 250 300 350 400 450 500
Ranges
50 − 335
40 − 240
25 − 150
15 − 75
DC AMPERES
DC VOLTS
DC AMPERES
DC VOLTS