OM-880 Page 9
the welding power source. To connect the Remote Con-
tactor and/or Amperage or Voltage Control to the RE-
MOTE-5 receptacle, align keyway, insert plug from the
Remote Control, and rotate threaded collar fully clock-
wise.
E
AD
BC
S-0005
Figure 3-6. Front View Of 5-Socket Amphenol Re-
ceptacle With Socket Designations
Receptacle RC3 socket connections to the welding
power source control circuitry are as follows:
Socket A: Contactor control switch connection.
Socket B: Contactor control switch connection.
Socket C: Amperage or voltage control connection
(maximum side).
Socket D: Amperage or voltage control connection
(minimum side).
Socket E: Amperage or voltage control connection
(wiper contact).
IMPORTANT: Use only one CV-2 receptacle at a time
for remote current and/or voltage control o r welding gen-
erator may not work properly.
3-3. REMOTE-14 RECEPTACLE INFORMATION
AND CONNECTIONS (Figures 3-7 And 4-1)

REMOTE-14

The 14-socket REMOTE-14 receptacle RC4 provides a
junction point for connecting a Remote Amperage/Volt-
age Control and/or a Remote Contactor Control or a
wire feeder providing switch closure for contactor con-
trol to the control circuitry of the welding generator. To
make connections, align keyway, insert plug fully into re-
ceptacle, and rotate threaded collar clockwise.
AJ
BKI
CLNH
DMG
EF
S-0004
Figure 3-7. Front View Of 14-Socket Amphenol
Receptacle With Socket Designations
The command signals required and the output signals
available at the sockets of receptacle RC4 b y means of
the welding generator control circuitry are as follows:
Socket A: Up to 10 amperes of 24 volts ac 60 Hz with
respect to socket G (circuit common), pro-
tected by circuit breaker CB6.
Socket B: Weld contactor control for 24 volts ac wire
feeders providing contact closure to socket
A.
Socket C: 0 to +10 volts dc with respect to Socket D;
reference voltage for output command sig-
nal depends on the AMPERAGE & VOLT-
AGE ADJUSTMENT control setting on the
unit.
Socket D: Control circuit common for remote control
device.
Socket E: Output command signal to wiper of remote
control potentiometer, 0 volts equals ma-
chine minimum; +10 volts equals machine
maximum.
Socket F: Not used.
Socket G: 24 and 120 volts ac circuit common.
Socket H: Not used.
Socket I: Up t o 1 0 amperes of 120 volts ac 60 Hz with
respect to socket G (circuit common), pro-
tected by circuit breaker CB5.
Socket J: Weld contactor control for 120 volts ac wire
feeders providing contact closure to socket
I.
Socket K: Machine chassis.
Socket L: Not used.
Socket M: Not used.
Socket N: Not used.
IMPORTANT: Use only one CV-2 receptacle at a time
for remote current and/or voltage control o r welding gen-
erator may not work properly.