4-4. Rear Panel Connections
6
6 | 7 | 8 | 9 |
|
1
4
2
1”Y” Adapter Gas Hose (Supplied)
2Shielding Gas Valve Fitting
Requires fitting with
3Weld Cable Terminal
4Jumper Weld Cable
5Weld Cable
6Optional Current Sensor Connections
7
8Power Switch
9Rating Label Location
5
3
4
Tools Needed:
5
9/16, 5/8 in
3/16 in
Ref. 800
4-5. 14-Pin Plug Information
|
|
| Pin* | Pin Information | |
|
|
| A | 24 volts ac with respect to socket G. | |
|
|
| B | Contact closure to A completes 24 volts ac contactor control circuit. | |
J | K | A | G | Circuit common for 24 volts AC circuit. | |
|
| ||||
I | B | C | +10 volts dc output to remote control with respect to socket D. | ||
|
| ||||
|
| L C | |||
H | N | D | Remote control circuit common. | ||
G | M | D | |||
|
| ||||
F | E |
| E | 0 to +10 volts dc input command signal from remote control with respect to socket D. | |
|
|
| H | Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts. | |
|
|
| F | Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes. |