SECTION 4 – OPERATION

4-1. Pendant Controls

2

1

3

4

Ref. ST-802 483-A / ST-199 348 / ST-199 350 / 199 343

Use Nameplates As A Voltage And Amperage Reference Only.

Controls are pendant mounted. An optional remote pendant extension cord is available.

1 Nameplate

Pendant has three nameplates stacked one on top of the other. Each nameplate contains the voltage and amperage range for a differ- ent size flux cored welding wire (for reference only).

Unit is shipped with 1.2 mm wire nameplate

on top. See Section 3-10 to change to 1.4 mm or 1.6 mm flux cored welding wire nameplate.

2 Voltage Control

Use control to set welding power source volt- age at the wire feeder. Numbers are for refer- ence only.

3 Wire Speed Control

Use control to adjust wire feed speed from 0 to 20 meters per minute.

.Match colored bands on voltage and wire speed controls to get an acceptable welding condition.

4 Jog Switch

Use Jog switch to momentarily feed welding wire at speed set on Wire Speed control with- out energizing welding circuit or shielding gas valve.

OM-197 509 Page 13

Page 17
Image 17
Miller Electric DS-2 manual Operation, Pendant Controls, Use Nameplates As a Voltage And Amperage Reference Only