2-5. Installing Drive Roll and Wire Inlet Guide
3
5
2
4
1
1Securing Screw
2Inlet Wire Guide
Loosen screw. Slide tip as close to drive rolls as possible without touch- ing. Tighten screw.
3Wire Tension Wheel
4Drive Roll
Install correct drive roll for wire size and type.
5 Drive Roll Tension Assembly
Turn nut one click to secure drive roll.
2-6. Installing Wire Spool and Adjusting Hub Tension
When a slight force is needed to turn spool, tension is set.
Tools Needed:
15/16 inST-072573-B
2-7. Electrical Service Guide
| 201 | 241 |
|
|
|
Input Voltage | 230 | 230 |
|
|
|
Input Amperes at Rated Output | 26 | 35 |
|
|
|
Max Recommended Standard Fuse or Circuit Breaker Rating in Amperes | 26 | 35 |
|
|
|
** Input Conductor Size in mm2 | 4 | 4 |
** Grounding Conductor Size in mm2 | 4 | 4 |
** Power cord supplied with the unit is sized for 230V operation. Larger power cord may be required for cable lengths greater than 3 meters. C onsult national and local regulations.