Installationstallation, cont’d

Rear Panel Connectors

Front panel features are shown on page 3-2.

1

2

3

INPUTS

5

6

7

8

OUTPUTS

 

4

PROGRAM

PREVIEW

 

 

 

 

 

 

 

 

 

 

 

PROGRAM

R/R-Y

R/R-Y

R/R-Y

R/R-Y

R/R-Y

R/R-Y

R/R-Y

R/R-Y

R

R

 

 

 

 

 

 

 

 

 

 

 

PREVIEW

G/Y

G/Y

G/Y

G/Y

G/Y

G/Y

G/Y

G/Y

G

G

 

B/B-Y

B/B-Y

B/B-Y

B/B-Y

B/B-Y

B/B-Y

B/B-Y

B/B-Y

B

B

REMOTE

 

100- 240 50/60 Hz

 

 

 

 

 

 

 

 

 

 

1.2A MAX.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCP

H/HV

H/HV

H/HV

H/HV

H/HV

H/HV

H/HV

H/HV

H/HV

H/HV

 

V

V

V

V

V

V

V

V

V

V

 

7

PROGRAM

DVI OUT

1

2

3

4

5

6

Figure 2-1 — SGS 408 rear panel

1

2

AC power connector — One standard AC power connector attaches the switcher to any power source from 100VAC to 240VAC, operating at 50 or 60 Hz.

Input connectors — Eight sets of five BNC female connectors for component video, RGsB, RGBS, and RGBHV input devices.

3

4

Output BNC connectors — Two sets of five BNC female connectors for output to RGBS or RGBHV devices. One set of connectors is dedicated to the program image, and one set to the preview image.

RCP port — One 4-pin female XLR connector that allows you to attach the RCP 1000 remote control panel to the SGS 408. Refer to the RCP 1000 User’s Manual for more information.

5RS-232 connector — One 9-pin D female connector that allows you to attach an ECP 1000 event control panel, a computer, or controlling device for remote control of the switcher.

6DVI output connector (optional) — One DVI connector that allows you to attach the switcher to a DVI output device. The connector is dedicated to the program image.

7Output 15-pin HD connectors — Two connectors for output to RGBS or RGBHV devices. One connector is dedicated to the program image, and one to the preview image. The connectors receive the same signals as the output BNC connectors.

Installation

To install the switcher, follow these general steps:

1

2

3

If desired, mount the switcher in a rack (see “Mounting the switcher” on page 2-3). Otherwise, install the rubber feet (see “Tabletop/desktop placement” on page 2-4).

Turn off power to the input and output devices, and unplug the power cables from them.

Attach the input and output devices to the switcher. See “Cabling” on page 2-4.

2-2 SGS 408 Switcher • Installation

Page 12
Image 12
Extron electronic manual Installationstallation, cont’d, Rear Panel Connectors, SGS 408 Switcher Installation