Serial Communication, cont’d

Command/response table

Symbol Definitions:

 

= CR/LF, • = space

 

X1 = Input number

1 – 8

X2

= Output number

1 = Program

 

 

2 = Preview

X3

= Memory preset

0 – 255

X4

= Contrast value

0 – 64

X5

= Brightness value

0 – 32

ASCII to HEX Conversion Table

X6

X7

X8

= Horizontal filter

0 – 7

= Vertical filter

0 – 7

= Test pattern type

1 = Color Bars

 

2

= Crosshatch

 

3

= Grayscale

 

4

= Crop

 

5

= Alternating pixels

X9

= Test pattern

0

= None

 

1

= Preview

 

2

= Program

 

3

= Program and preview

X10

= Effect type

0 = Cut

3 = Hard-edged wipe

6 = Plus

 

1 = Dissolve

4

= Soft curtain

7

= Square

 

2 = Soft-edged wipe

5

= Hard curtain

8

= Title

X11

= Transition type If X10 = 0 or 1

If X10 = 2 or 3

If X10 = 4 or 5

If X10 = 6 or 7

X11 = 0

0 = Left to right

0 = In from left and

0 = In

 

1 = Right to left

 

right edges

1 = Out

 

2 = Top to bottom

1

= Out to left and

If X10 = 8

 

3 = Bottom to top

 

right edges

1 = Window

 

 

2

= In from top and

2 = Key

 

 

 

bottom edges

 

 

 

3

= Out to top and

 

 

 

 

bottom edges

 

X12

= Duration period 0 – 48 (0.2 – 5.0 seconds), where 0 = 0.2 seconds, and each increment of the duration period adds 0.1 second to the duration time. A duration period of 25 is equal to 0.2 + (25 x 0.1) = 2.7 seconds. A duration period of 48 is equal to

0.2 + (48 x 0.1) = 5.0 seconds.

X13

X14

= Output resolution

0 = 640 x 480

4 = 852 x 480

8 = 1360 x 765

12

= 720p

 

 

1 = 800 x 600

5 = 1024 x 768

9 = 1365 x 1024

13

= 1080i

 

 

2 = 832 x 624

6 = 1280 x 768

10 = 1400 x 1050

14

= 1080p

 

 

3 = 848 x 480

7 = 1280 x 1024

11 = 576p

 

 

 

= Vertical refresh rate

If X13 = 0, 1, 5

If X13 = 3, 4,

If X13

= 6

If X13 = 7, 10,

If X13 = 2

If X13 = 11

 

 

8, 9,

 

 

13

 

 

 

 

 

12, 14

 

 

 

 

 

 

 

0 = 50 Hz

0 = 60 Hz

0 = 56 Hz

0 = 50 Hz

0 = 60 Hz

0 = 50 Hz

 

1 = 60 Hz

1 = Lock*

1 = Lock*

1 = 60 Hz

1 = 75 Hz

1 = Lock*

 

2 = 75 Hz

 

 

 

2 = Lock*

2 = Lock*

 

 

3 = Lock*

 

 

 

 

 

 

 

* Locked to the current vertical refresh rate of input 1.

4-4 SGS 408 Switcher • Serial Communication

Page 46
Image 46
Extron electronic SGS 408 manual Serial Communication, cont’d, Command/response table