When the switcher receives an SIS command and determines that it is valid, it performs the command and sends a response to the host device. If the switcher is unable to perform the command because the command is invalid or contains invalid parameters, the switcher returns an error response to the host. The error response codes are:

E01 — Invalid input number (too large)

E10 — Invalid command

E11 — Invalid preset

E12 — Invalid output number (too large)

E13 — Invalid value (out of range)

E23 — Checksum error

Using the command/response table

The command/response table begins on the next page. Lower case letters are acceptable in the command field only where indicated. Symbols are used throughout the table to represent variables in the command/response fields. Symbol definitions are shown at the beginning of the response table, as is an ASCII-to-hexadecimal conversion table. Command and response examples are shown throughout the table.