4-3. Trigger Hold Switch

1

1 Trigger Hold Switch

Trigger hold allows the operator to weld with- out holding the gun trigger.

 

 

802 828-A

To use the trigger hold function, place the

seconds before releasing it. Welding will

 

trigger hold switch in the On position.

continue when the trigger is released.

The operator must hold the trigger for a mini-

To stop welding, press the trigger again.

 

mum of 2 seconds, but not longer than 6

4-4. Optional Voltage Control And Digital Meters

1

2

3

1 Voltmeter

Displays actual or preset voltage from welding power source through the 14–pin control cable.

2 Wire Speed Meter

Factory set to display inches per minute. If display of meters per min- ute is desired, see Section 3-8.

3 Voltage Control

Use control to adjust voltage output of welding power source.

.You can adjust the preset volt- age display on the wire feeder to match your power source’s display by adjusting P2 on mo- tor control board PC1. See Section 5-2 for location of P2.