RIDGID WL1200LS1 manual Starting switch Burned switch con

Models: WL1200LS1

1 56
Download 56 pages 39.65 Kb
Page 50
Image 50

Troubleshooting (continued)

Motor (continued)

Trouble

 

Probable Cause

 

Remedy

 

 

 

 

 

 

 

 

 

 

Starting switch in

1.

Burned switch con-

1.

Have switch replaced and request

motor will not oper-

 

tacts (due to

 

a voltage check from the power

ate.

 

extended hold-in peri-

 

company.

 

 

ods caused by low

 

 

 

 

line voltage, etc.)

 

 

 

2.

Shorted capacitor

2.

Have capacitor tested and replace

 

 

 

 

if defective.

 

3.

Loose or broken con-

3.

Have wiring checked and repaired.

 

 

nections.

 

 

 

 

 

 

 

Motor stalls

1.

Starting switch not

1.

Have switch replaced.

(resulting in blown

 

operating.

 

 

fuses or tripped circuit

2.

Voltage too low to

2.

Request voltage check from the

breakers).

 

permit motor to reach

 

power company.

 

 

operating speed.

 

 

 

3.

Fuses or circuit break-

3.

Install proper size fuses or circuit

 

 

ers do not have suffi-

 

breakers.

 

 

cient capacity.

 

 

 

 

 

 

 

Frequent opening of

1.

Motor overloaded.

1.

Take shallower cuts.

fuses or circuit break-

2. Fuses or circuit break-

2.

Install proper size fuses or circuit

ers.

 

ers do not have suffi-

 

breakers.

 

 

cient capacity.

 

 

 

3.

Starting switch not

3.

Have switch replaced.

 

 

operating (motor does

 

 

 

 

not reach speed).

 

 

 

 

 

 

 