Miller Electric OM-2241 manual Weld Output Terminals And Selecting Cable Sizes, 10 − 60% 60 − 100%

Models: OM-2241

1 32
Download 32 pages 4.13 Kb
Page 17
Image 17
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your distributor for
the mm2 equivalent weld cable sizes.S-0007-E
OM-2241 Page 13

3-8. Weld Output Terminals And Selecting Cable Sizes

YTurn off power before connecting to weld out- put terminals.

YDo not use worn, dam- aged, undersized, or poorly spliced cables.

Negative

Stainless Steel/

Aluminum

All Other

Materials

 

 

Total Cable (Copper) Length In Weld Circuit Not Exceeding

 

 

 

 

 

 

 

 

 

 

 

100 ft (30 m) Or Less

150 ft

200 ft

250 ft

300 ft

350 ft

400 ft

 

(45 m)

(60 m)

(70 m)

(90 m)

(105 m)

(120 m)

 

 

 

 

 

 

 

 

 

 

 

 

Welding

10 − 60%

60 − 100%

 

 

10 − 100% Duty Cycle

 

 

Amperes

Duty Cycle

Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

4

4

4

3

2

1

1/0

1/0

 

 

 

 

 

 

 

 

 

150

3

3

2

1

1/0

2/0

3/0

3/0

 

 

 

 

 

 

 

 

 

200

3

2

1

1/0

2/0

3/0

4/0

4/0

 

 

 

 

 

 

 

 

 

250

2

1

1/0

2/0

3/0

4/0

2-2/0

2-2/0

 

 

 

 

 

 

 

 

 

300

1

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

 

 

 

 

 

 

 

 

 

350

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

2-4/0

 

 

 

 

 

 

 

 

 

400

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

2-4/0

 

 

 

 

 

 

 

 

 

500

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-3/0

 

 

 

 

 

 

 

 

 

600

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

3-4/0

 

 

 

 

 

 

 

 

 

700

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

3-4/0

4-4/0

 

 

 

 

 

 

 

 

 

Page 17
Image 17
Miller Electric OM-2241 manual Weld Output Terminals And Selecting Cable Sizes, 10 − 60% 60 − 100%, Duty Cycle