Miller Electric OM-2241 manual Remote 14 Receptacle RC8 Information

Models: OM-2241

1 32
Download 32 pages 4.13 Kb
Page 18
Image 18

3-9. Remote 14 Receptacle RC8

Y Turn off power before con- necting to receptacle.

1 Remote 14 Receptacle RC8 Connect feeder to RC8.

1

A

J

B

K

I

 

 

C

L N

H

D

M

G

 

E

F

Ref. 800 166-D

3-10. Remote 14 Receptacle RC8 Information

 

Socket

Information

 

A

24 volts ac. Protected by circuit breaker CB2.

24 VOLTS AC

B

Contact closure to A completes 24 volts ac contactor control circuit.

 

 

C

Command reference; 0 to +10 volts dc.

REMOTE OUTPUT CONTROL

D

Remote control circuit common.

 

E

0 to +10 volts dc input command signal from remote control.

 

F

Current feedback; 1 volt per 100 amperes.

 

H

Voltage feedback; 1 volt per 10 arc volts.

115 VOLTS AC

I

115 volts, 15 amperes, 60 Hz ac. Protected by circuit breaker CB1.

J

Contact closure to I completes 115 volts ac contactor control circuit.

 

GND

K

Chassis common.

G

Circuit common for 24 and 115 volts ac circuits.

 

REMOTE POWER ON/OFF

*

To remote On/Off switch.

 

 

REMOTE VOLTAGE SENSING

*

Voltage sensing signal from Negative (−) weld output terminal.

*

Voltage sensing signal from Positive (+) weld output terminal.

 

* Not Used

 

 

OM-2241 Page 14

Page 18
Image 18
Miller Electric OM-2241 manual Remote 14 Receptacle RC8 Information, Turn off power before con- necting to receptacle