5-9. Guidelines For Installing Customer-Supplied Emergency Air Shutdown Valve

A customer-supplied emergency air shutdown valve can be installed to stop the engine imme- diately in emergency situations.

These guidelines show the typical installation of a Gator ESD 175-275-L3 air shutdown valve. Installation of other air shutdown valves may differ from that shown. Contact the air shut- down valve manufacturer or a Factory Autho- rized Service Agent for additional installation and operation information.

 

!

Stop engine, and let cool.

 

!

Disconnect battery negative (−) cable.

 

Open doors and remove side panels.

 

1

Air Cleaner

 

2

2 in (51 mm) Hose Clamp

 

3

1-3/4 x 2 in (44 x 51 mm) Rubber Hose

 

4

Air Shutdown Valve

 

 

(Gator ESD 175-275-L3)

 

5

1-3/4 x 16-1/2 in (44 x 419 mm) Flexible

 

 

Radiator Hose (NAPA Part No. FM68)

 

. Use thick-walled rubber hose. Do not use

 

 

heater hose. (Heater hose could let dirt into

 

 

engine.)

 

6

Engine Air Inlet

7

7

Shutdown Control

8

42 in (1067 mm) Shutdown Control Cable

 

 

(Supplied By Gator)

 

9

Shutdown Valve Reset Lever

 

Install components as shown.

Be sure air shutdown valve is installed with air flow arrow pointing toward air inlet. Use cable ties to keep air shutdown system components away from hot or moving parts.

Verify the emergency air shutdown system op- erates correctly. After testing, use reset lever to reset air shutdown valve.

Reinstall side panels and close doors. Reconnect battery negative (−) cable.

1

2

8

3

Mount on lower

front panel

4 9

5 7

6

803 390