8-11. Troubleshooting

A. Welding

Trouble

Remedy

 

 

No weld output.

Check control settings.

 

 

 

Check weld connections.

 

 

 

Disconnect equipment from generator power receptacles during start-up.

 

 

 

If using remote control, be sure mode switch is in a position that provides output control at Remote 14

 

receptacle (see Sections 5-8and 6-1).

 

 

 

Check, repair, or replace remote control.

 

 

 

Unit overheated. Allow unit to run so fan cools unit (see Section 4-3).

 

 

 

Have Factory Authorized Service Agent check brushes, slip rings, power board PC7, voltage regulator

 

board PC8, interconnecting board PC2, and control board PC1.

 

 

Ammeter and voltmeter do not work

Restart the engine.

after unit has run out of fuel.

 

 

 

Low weld output.

Check control settings.

 

 

 

Place V/A Control switch in Panel position, or move switch to Remote position and connect remote

 

amperage/voltage control to Remote 14 receptacle RC14 (see Section 5-8).

 

 

 

Check and clean air cleaner as necessary (see Section 8-4).

 

 

 

Check engine speed, and adjust if necessary (see Section 8-8).

 

 

 

If using remote control, be sure mode switch is in a position that provides output control at Remote 14

 

receptacle RC14 (see Sections 5-8and 6-1).

 

 

 

Have Factory Authorized Service Agent check brushes, slip rings, voltage regulator board PC8, intercon-

 

necting board PC2, and control board PC1.

 

 

 

See engine manual.

 

 

High weld output.

Check control settings.

 

 

 

Check engine speed, and adjust if necessary (see Section 8-8).

 

 

 

Check for obstructed movement of throttle solenoid linkage.

 

 

 

Have Factory Authorized Service Agent check voltage regulator board PC8 and control board PC1.

 

 

Weld output cannot be adjusted.

Check position of V/A Control switch (see Section 6-1).

 

 

 

Have Factory Authorized Service Agent check voltage regulator board PC8 and control board PC1.

 

 

Erratic weld output.

Check control settings.

 

 

 

Clean and tighten connections both inside and outside unit.

 

 

 

Check and secure lead connections to A/V control.

 

 

 

Be sure connection to work piece is clean and tight.

 

 

 

Remove excessive coils from weld cables.

 

 

 

Use dry, properly stored electrodes.

 

 

 

Check engine speed, and adjust if necessary (see Section 8-8).

 

 

 

Have Factory Authorized Service Agent check brushes, slip rings, voltage regulator board PC8, intercon-

 

necting board PC2, and control board PC1.

 

 