4-7. Remote 14 Receptacle Information

A K

J I

B

 

 

C

L N

H

D

M

G

 

E

F

ST-801 192

 

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by circuit breaker CB2.

 

 

 

B

Contact closure to A completes 24 volts ac con-

 

 

tactor control circuit.

115 VOLTS AC

I

115 volts ac. Protected by circuit breaker CB1.

 

 

 

J

Contact closure to I completes 115 volts ac con-

 

 

tactor control circuit.

 

C

Output to remote control; 0 to +10 volts dc, +10

 

 

volts dc in MIG mode.

REMOTE

D

Remote control circuit common.

OUTPUT

CONTROL

E

0 to +10 volts dc input command signal from re-

 

 

 

mote control.

 

H

Voltage feedback; +1 volt dc per 10 output recep-

A/V

 

tacle volts.

 

 

AMPERAGE

F

Current feedback; +1 volt dc per 100 amperes.

VOLTAGE

 

 

 

M

CC/CV select

 

G

Circuit common for 24 and 115 volts ac circuits.

GND

K

Chassis common.

 

*The remaining sockets are not used.

4-8. Electrical Service Guide

NOTICE − INCORRECT INPUT POWER can damage this welding power source. This welding power source requires a CONTINUOUS supply of input power at rated frequency(+10%) and voltage (+10%). Phase to ground voltage shall not exceed +10% of rated input voltage. Do not use a genera- tor with automatic idle device (that idles engine when no load is sensed) to supply input power to this welding power source.

NOTICE − Actual input voltage should not be 10% less than minimum and/or 10% more than maximum input voltages listed in table. If actual input voltage is outside this range, output may not be be available.

Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda- tions are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source.

 

50/60 Hz Three Phase

 

 

Input Voltage

400

 

 

Input Amperes At Rated Output

18

 

 

Max Recommended Standard Fuse Rating In Amperes 1

 

Time-Delay 2

20

Normal Operating 3

25

Min Input Conductor Size In AWG 4

14

Max Recommended Input Conductor Length In Feet (Meters)

133

(41)

 

 

 

Min Grounding Conductor Size In AWG 4

14

Reference: 2005 National Electrical Code (NEC) (includes article 630)

 

1Consult factory for circuit breaker applications.

2“Time-Delay” fuses are UL class “RK5” .

3“Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and above).

4Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table 310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.

OM-217 769 Page 18

Page 22
Image 22
Miller Electric XMT 400 manual Remote 14 Receptacle Information, Electrical Service Guide