Milwaukee 2216-20 manual Continuity

Models: 2216-20

1 20
Download 20 pages 8.96 Kb
Page 8
Image 8

(6) Continuity

Range

Resolution

Accuracy

 

 

 

600.0Ω

0.1Ω

±(1% reading + 5 digits)

 

 

 

Open Circuit Voltage: Approx. 0.6V

Continuity: Built-in buzzer sounds when measured resistance is less than 30Ω and sounds off when measured resistance is more than 200Ω, Between 30Ω to 200Ω the buzzer maybe sound or off either.

Continuity Indicator: 2.7KHz Tone Buzzer

Response Time of Buzzer: < 500 μsec.

Response Time of LCD reading: < 1.5 sec.

Overload Protection: AC/DC 600V for 10 second.

(7) Capacitance

Range

Resolution

Accuracy

 

 

 

100.0µF

0.01µF

±(1.9% reading + 2 digits)

 

 

1000µF

1µF

 

 

 

 

Response Time when measuring 1000µF: < 2.5 sec.

Overload Protection: AC/DC 600V for 10 second.

(8) Frequency

Range

Resolution

Min. Sensitivity

Accuracy

 

 

 

 

100.00Hz

0.01Hz

> 10.0Vp-p

 

 

 

 

 

1000.0Hz

0.1Hz

> 10.0Vp-p

±(0.1% reading + 2 digits)

 

 

 

10.000kHz

0.001Hz

> 10.0Vp-p

 

 

 

 

 

50.00kHz

0.01Hz

> 10.0Vp-p

 

 

 

 

 

Max. Sensitivity: 600V rms

Response Time: < 1.2 sec. when measuring bigger than 2.00Hz signal.

Overload Protection: AC/DC 720V for 10 second.

(9)Over-range Indication

Display “OL” or “-OL” when the reading exceeds 10% of the full scale except the full scale is 10000 counts.

(10)Rotary Switch

In order to prevent a “0” reading, the contacts about the input signal must be made properly before the contact of the function selection.

6