Functions |
ASSEMBLY
|
| Dial Position | Range | Resolution | Accuracy | |
|
|
| Voltage AC | 600mV/6V | 0.1mV/0.001V/ | ±(1.0% + 3 dgt) (45~500Hz) |
|
|
| 60/600V | 0.01V/0.1V | ±(2.0% + 3 dgt) (500~1000Hz) | |
|
|
|
| |||
|
|
| Voltage DC | 600mV/6/60/600V | 0.1mV/0.001V/ | ±(0.5% + 2 dgt) |
|
|
| ||||
|
|
| 0.01V/0.1V | |||
|
|
|
|
|
| |
| Low Input | 600V | 0.1V | ±(2.0% + 3 dgt) DC,AC : 45~500Hz | ||
Impedance | ||||||
Hz | Hertz | 99.99/999.9Hz | 0.01Hz/0.1Hz/ | ±(0.1% + 2 dgt) | ||
9.999/50.00kHz | 0.001kHz/0.01kHz | Sensitivity: | ||||
|
|
|
| 600Ω/6/60/600kΩ | 0.1/0.001k/0.01k/ | ±(1.0% + 5 dgt) |
WARNING To avoid an electrical hazard, turn the Rotary Dial to OFF and disconnect the test leads before replacing batteries.
Loading/Changing the Batteries
Replace batteries when the Low Battery indicator is displayed.
1.Turn Rotary Dial to OFF and disconnect the test leads.
2.Unscrew and remove battery door.
3.Insert two (2) AA batteries, according to the polarity marked in the battery compartment
4.Close the battery door and
tighten screw securely.
Resistance | 6MΩ | 0.1k/0.001M Ω | ±(1.0% + 5 dgt) |
OPERATION
|
|
| 40MΩ | 0.01M Ω | ±(2.0% + 5 dgt) |
|
| Continuity | Cont Buzzer |
| Buzzer sounds at 30Ω or less |
|
|
| |||
|
|
|
|
| |
|
|
|
|
|
|
|
| Capacitance | 100μF | 0.1μF | ±(1.9% + 2 dgt) |
|
| 1000μF | 1μF | ||
|
|
|
| ||
|
| Current AC | 6A | 0.001A/0.01A | ±(1.5% + 3 dgt) (45~500Hz) |
|
| 10A | |||
|
|
|
|
| |
|
| Current DC | 6A | 0.001A/0.01A | ±(1.0% + 3 dgt) |
|
| ||||
|
| 10A | |||
|
|
|
|
| |
|
| Temperature† | - 40ºC ~ 400ºC | 0.1°C | ±(1.0% + 10 dgt) |
|
| 0.2°F | ±(1.0% + 18 dgt) | ||
|
|
|
WARNING Only use Milwaukee test leads with the MILWAUKEE DMM. Inspect test leads for continuity before each use. Do not use if the readings are high or noisy.
Before Use
Confirm the Rotary Dial is set to the correct position, the instrument is set to the correct measurement mode, and the Data hold function is disabled. Oth- erwise, desired measurement cannot be made.
LCD Backlight
DC Voltage
DANGER To avoid electrical shock: Never make measurement on a circuit in which voltage over DC600V exists. Do not use with the Battery Cover removed. Keep fingers behind the guards and away from test lead tips during measurements.
1. Set the Dial to position.
2. Connect the red test lead to the VΩ terminal and the
†Temperature Range, Resolution and Accuracy are for the DMM. Temperature Probe may have different specifications.
*These instruments are
*Input impedance: Voltage DC: 10MΩ; Voltage AC:
10MΩ // less than 100pF;
*Overload protection:
Voltage DC, voltage AC,
Current DC & Current AC: AC/DC 20A for 10 sec. Resistance, Continuity, Capacitance and Tem- perature: AC/DC 600V for 10 second
*Maximum measurement time: 1 minute at 10A, rest time 20 minutes minimum
*Minimum frquency measurement is 2Hz
*Minimum AC Current measurement is 0.040A
*For AC Voltage, AC Current and
Add 2.5% for C.F. 2.0 ~ 2.5 Add 4.0% for C.F. 2.5 ~ 3.0
Max. Crest Factor: 1.6 for 6600 ~ 5000 digits
2.0for 5000 ~ 3000 digits
3.0for 3000 ~ 0 digits
*Measurement accuracy of square wave and trun- cated waveforms at 1kHz is unspecified.
Symbology
Read Operator’s Manual
Double insulation
Risk of electric shock
Earth
Danger, Warning, or Caution - Consult the operators manual for additional safety information.
Battery compartment
European Conformity Mark
Underwriters Laboratories, Inc.,
United States and Canada
Classification of transient Cat III overvoltages, based on nominal
line voltage to earth.
Fuse
Do not dispose of this product as unsorted municipal waste.
The LCD backlight will turn off after about 10 min- utes of inactivity. Press the backlight button to turn the backlight on again.
Making a Measurement
AC Voltage
DANGER To avoid electrical shock: Never make measurement on a circuit in which voltage over AC600V exists.
Do not use with the Battery Cover removed.
Keep fingers behind the guards and away from test lead tips during measurements.
1. Set the Dial to position.
2. Connect the red test lead to the VΩ terminal and the black test lead to the COM terminal.
3. Connect the test leads to the circuit under test. The read- ing is displayed.
CAUTION Readings may fluctuate or be influenced in noisy environment.
black test lead to the COM terminal.
3. Connect the red test lead to the positive (+) side and black test leads to the negative
is displayed. A reversed connection is indicated as a negative value.
Automatic voltage detection (AC or DC).
1. Set the Dial to
2. Connect the red test lead to the VΩ terminal and the black test lead to the COM terminal.
3. AC: Connect the test leads to the circuit under test. The reading is displayed.
DC: Connect the red test lead to the positive (+) side and
black test leads to the negative
CAUTION Do not use the DMM to measure voltages in circuits that could be damaged by the DMM’s low input impedance less than approximately 4kΩ.