Milwaukee 2217-20 manual Lo-Z, Functions, Assembly, Operation, Symbology

Models: 2217-20

1 13
Download 13 pages 41.89 Kb
Page 3
Image 3
Functions

Functions

ASSEMBLY

 

 

Dial Position

Range

Resolution

Accuracy

 

 

 

Voltage AC

600mV/6V

0.1mV/0.001V/

±(1.0% + 3 dgt) (45~500Hz)

 

 

 

60/600V

0.01V/0.1V

±(2.0% + 3 dgt) (500~1000Hz)

 

 

 

 

 

 

 

Voltage DC

600mV/6/60/600V

0.1mV/0.001V/

±(0.5% + 2 dgt)

 

 

 

 

 

 

0.01V/0.1V

 

 

 

 

 

 

Lo-Z

Low Input

600V

0.1V

±(2.0% + 3 dgt) DC,AC : 45~500Hz

Impedance

Hz

Hertz

99.99/999.9Hz

0.01Hz/0.1Hz/

±(0.1% + 2 dgt)

9.999/50.00kHz

0.001kHz/0.01kHz

Sensitivity: 10Vp-p

 

 

 

 

600Ω/6/60/600kΩ

0.1/0.001k/0.01k/

±(1.0% + 5 dgt)

WARNING To avoid an electrical hazard, turn the Rotary Dial to OFF and disconnect the test leads before replacing batteries.

Loading/Changing the Batteries

Replace batteries when the Low Battery indicator is displayed.

1.Turn Rotary Dial to OFF and disconnect the test leads.

2.Unscrew and remove battery door.

3.Insert two (2) AA batteries, according to the polarity marked in the battery compartment

4.Close the battery door and

tighten screw securely.

Resistance

6MΩ

0.1k/0.001M Ω

±(1.0% + 5 dgt)

OPERATION

 

 

 

40MΩ

0.01M Ω

±(2.0% + 5 dgt)

 

 

Continuity

Cont Buzzer

 

Buzzer sounds at 30Ω or less

 

 

0-600.0Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacitance

100μF

0.1μF

±(1.9% + 2 dgt)

 

 

1000μF

1μF

 

 

 

 

 

 

Current AC

6A

0.001A/0.01A

±(1.5% + 3 dgt) (45~500Hz)

 

 

10A

 

 

 

 

 

 

 

Current DC

6A

0.001A/0.01A

±(1.0% + 3 dgt)

 

 

 

 

10A

 

 

 

 

 

 

 

Temperature

- 40ºC ~ 400ºC

0.1°C

±(1.0% + 10 dgt)

 

 

-40ºF ~ 752ºF

0.2°F

±(1.0% + 18 dgt)

 

 

 

ASSEMBLY WARNING Only use Milwaukee test leads with the MILWAUKEE DMM. Inspect test leads for continuity before each use. Do not use if the readings are high or noisy.

Before Use

Confirm the Rotary Dial is set to the correct position, the instrument is set to the correct measurement mode, and the Data hold function is disabled. Oth- erwise, desired measurement cannot be made.

Lo-Z LCD Backlight

DC Voltage

OPERATION DANGER To avoid electrical shock: Never make measurement on a circuit in which voltage over DC600V exists. Do not use with the Battery Cover removed. Keep fingers behind the guards and away from test lead tips during measurements.

1. Set the Dial to SymbologyManual backgroundManual background position.

2. Connect the red test lead to the VΩ terminal and the

Temperature Range, Resolution and Accuracy are for the DMM. Temperature Probe may have different specifications.

*These instruments are True-RMS sensing. All voltage and current readings are True-RMS val- ues.

*Input impedance: Voltage DC: 10MΩ; Voltage AC:

10MΩ // less than 100pF; Lo-z: 4kΩ approximately

*Overload protection:

Voltage DC, voltage AC, Lo-Z Voltage and Herts: AC/DC 720V for 10 second

Current DC & Current AC: AC/DC 20A for 10 sec. Resistance, Continuity, Capacitance and Tem- perature: AC/DC 600V for 10 second

*Maximum measurement time: 1 minute at 10A, rest time 20 minutes minimum

*Minimum frquency measurement is 2Hz

*Minimum AC Current measurement is 0.040A

*For AC Voltage, AC Current and Lo-z: Additional Accuracy by Crest Factor (C.F.): Add 1.0% for C.F. 1.4 ~ 2.0

Add 2.5% for C.F. 2.0 ~ 2.5 Add 4.0% for C.F. 2.5 ~ 3.0

Max. Crest Factor: 1.6 for 6600 ~ 5000 digits

2.0for 5000 ~ 3000 digits

3.0for 3000 ~ 0 digits

*Measurement accuracy of square wave and trun- cated waveforms at 1kHz is unspecified.

Symbology

Read Operator’s Manual

Double insulation

Risk of electric shock

Earth

Danger, Warning, or Caution - Consult the operators manual for additional safety information.

Battery compartment

European Conformity Mark

Underwriters Laboratories, Inc.,

United States and Canada

Classification of transient Cat III overvoltages, based on nominal

line voltage to earth.

Fuse

Do not dispose of this product as unsorted municipal waste.

The LCD backlight will turn off after about 10 min- utes of inactivity. Press the backlight button Manual background to turn the backlight on again.

Making a Measurement

AC Voltage

Manual background DANGER To avoid electrical shock: Never make measurement on a circuit in which voltage over AC600V exists.

Do not use with the Battery Cover removed.

Keep fingers behind the guards and away from test lead tips during measurements.

1. Set the Dial to Manual background position.

2. Connect the red test lead to the VΩ terminal and the black test lead to the COM terminal.

3. Connect the test leads to the circuit under test. The read- ing is displayed.

Manual backgroundManual background CAUTION Readings may fluctuate or be influenced in noisy environment.

black test lead to the COM terminal.

3. Connect the red test lead to the positive (+) side and black test leads to the negative (-) side of the cir- cuit under test. The reading

is displayed. A reversed connection is indicated as a negative value.

Lo-ZLow Input Impedance

Automatic voltage detection (AC or DC).

1. Set the Dial to Lo-Zposition.

2. Connect the red test lead to the VΩ terminal and the black test lead to the COM terminal.

3. AC: Connect the test leads to the circuit under test. The reading is displayed.

DC: Connect the red test lead to the positive (+) side and

black test leads to the negative (-) side of the circuit under test. The reading is displayed. A reversed connection is indicated as a negative value.

CAUTION Do not use the DMM to measure voltages in circuits that could be damaged by the DMM’s low input impedance less than approximately 4kΩ.

4

5

Page 3
Image 3
Milwaukee 2217-20 manual Lo-Z, Functions, Assembly, Operation, Symbology