Mitsubishi A1SJ71E71N-B5T Designation, Contents, Display LED, Refer to, Operation mode setting

Models: AJ71E71N-B5T A1SJ71E71N-B2 AJ71E71N-B2 A1SJ71E71N-B5T E71N-U-HW

1 19
Download 19 pages 2.81 Kb
Page 11
Image 11
Designation

No

 

 

Designation

 

 

 

Contents

 

1)

 

Display LED

 

Refer to (1)

 

 

2)

 

Operation mode setting

 

Refer to (2)

 

 

 

switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3)

 

Exchange condition

 

Refer to (3)

 

 

 

setting switch

 

 

 

 

 

 

 

 

 

 

4)

 

10BASE-T connector

 

Connector for connecting the E71 to the 10BASE-T.

 

 

 

 

 

 

Lamp for verifying if power is being supplied to the

 

 

 

 

 

 

transceiver when used as 10BASE5.

5)

 

External power supply

 

ON:

Power supplying

 

 

indicator lamp

 

OFF:

Power not supplied

 

 

 

 

 

 

 

 

 

 

 

When connecting with 10BASE-T, verification is

 

 

 

 

 

 

unnecessary.

 

 

 

 

 

 

 

Power source terminals for power source supply to the

 

 

External power supply

 

transceiver in the connection of 10BASE5. (14.08 V to

6)

 

 

15.75 V)

 

 

 

terminal

 

 

 

 

 

 

When connecting with 10BASE-T, verification is

 

 

 

 

 

 

 

 

 

 

 

 

unnecessary.

 

 

 

 

 

 

 

Connector for connecting the E71 to the 10BASE5.

7)

 

AUI cable connector

 

(For connection of 10BASE5-use AUI cable (transceiver

 

 

 

 

 

 

cable))

 

 

 

8)

 

10BASE2 connector

 

Connector for connecting the E71 to the 10BASE2.

(1) Display LED display contents

 

 

 

 

 

 

 

 

 

 

Display LED

 

Display contents

 

When lamp is lit

Lamp is not lit

RUN

 

 

Normal operation display

 

Normal

Error

RDY

 

 

Exchange ready end display

Starts flashing when

On-line Operations

 

 

begin

 

 

 

 

 

 

 

 

 

 

BSY

 

 

Exchange processing executing

Turns on when exchange processing

 

 

display

 

 

with remote node is being executed.

 

 

 

 

 

 

SW.ERR.

 

(For system)

 

 

COM.ERR.

 

Exchange error detection display

Exchange error

Normal

CPU R/W

 

Exchange processing executing

Exchanging

Not exchanging

 

with PLC CPU display

 

 

 

 

 

 

 

 

BUF1 to

 

Display of communication line

 

 

 

connection status of connection

Open completed

Closed status

BUF8

 

 

 

 

No.n corresponding to BUFn.

 

 

 

 

 

 

 

 

TEST

 

 

Self diagnostic executing display

Self diagnosis

Self diagnosis

 

 

 

 

 

 

 

 

executing

completed

TEST ERR.

 

Self diagnosis results display

Error

Normal

5

Page 11
Image 11
Mitsubishi A1SJ71E71N-B5T Designation, Contents, Display LED, Refer to, Operation mode setting, switch, Exchange condition