Mitsubishi Electronics DX-TL950E operation manual SUPER, HIGH, STDSTANDARD, BASIC, Long, Short

Models: DX-TL950E

1 90
Download 90 pages 24.16 Kb
Page 22
Image 22

Basic Operations (continued)

Setting the recording interval and recording picture quality for normal recording

To perform normal recording, “PPS” and “GRADE” must be set for each camera.

Setting of “PPS” ( default : “2.5P” )

“5P”, “2.5P”, “1.667P”, “1.25P”, “1P”, “0.833P”, “0.625P”, “0.5P”, “0.2P”, “0.1P”, “0.05P”, “0.025P”, “- - - - - -”

“- - - - - -” : Recording cannot be performed with camera set to this item.

Available recording intervals will vary according to the number of cameras operating or ALARM RE- CORDING settings ( see page 41). Interval dis- plays will be according to the chart.

Setting of “GRADE” ( default : “STD” )

“SUPER”, “HIGH”, “STD”(STANDARD), “BASIC”, “LONG”

Example : Set “PPS” of camera number “1 ” to “0.5P” and “GRADE” to “HIGH” for normal recording.

1.Press the SET UP button to display the <SETTINGS> screen.

2.Turn the JOG dial to move the cursor to “RECORD SETTINGS” and turn the SHUTTLE ring clockwise.

The <RECORD SETTINGS> screen appears.

<RECORD SETTINGS>

 

 

>>ALARM SETTING

 

 

RECORD SETTING

 

5S

ALARM REC DURATION

PRE ALARM REC

( S )

S

MOTION DET REC

 

ALARM

3.Turn the JOG dial to move the cursor to “RECORD SETTING” and then turn the SHUTTLE ring clockwise.

The <RECORD SETTING> screen appears.

<RECORD SETTING>

Camera selection during alarm recording

 

 

 

 

 

 

 

 

 

<RECORD SETTING>

 

>>ALARM CH

 

NO

PPS

GRADE

A-

PPS

 

A-GRADE

1

2.5P

STD

2.5P

 

STD

2

2.5P

STD

2.5P

 

STD

3

2.5P

STD

2.5P

 

STD

4

2.5P

STD

2.5P

 

STD

5

2.5P

STD

2.5P

 

STD

6

2.5P

STD

2.5P

 

STD

7

2.5P

STD

2.5P

 

STD

8

2.5P

STD

2.5P

 

STD

9

2.5P

STD

2.5P

 

STD

<ESTD REC>

 

D H

M

About <ESTD REC>

The estimated recordable time is displayed as <ESTD REC> depending on the “PPS” and “GRADE” settings. (The time will not change when changing the alarm recording settings.)

4.Turn the JOG dial to select “1 ” , and then turn the SHUTTLE ring clockwise.

The “PPS” setting reverses in color.

<RECORD SETTING>

ALARM CH

NO

PPS

GRADE

A-PPS

A-GRADE

1

2.5P

STD

2.5P

STD

2

2.5P

STD

2.5P

STD

3

2.5P

STD

2.5P

STD

4

2.5P

STD

2.5P

STD

5

2.5P

STD

2.5P

STD

6

2.5P

STD

2.5P

STD

7

2.5P

STD

2.5P

STD

8

2.5P

STD

2.5P

STD

9

2.5P

STD

2.5P

STD

<ESTD REC>

 

D H

M

5.Turn the SHUTTLE ring clockwise again.

The background of the “PPS” setting turns red and flashes.

<RECORD SETTING>

ALARM CH

NO

PPS

GRADE

A-PPS

A-GRADE

1

2.5P

 

STD

2.5P

STD

2

2.5P

 

STD

2.5P

STD

3

2.5P

STD

2.5P

STD

4

2.5P

STD

2.5P

STD

5

2.5P

STD

2.5P

STD

6

2.5P

STD

2.5P

STD

7

2.5P

STD

2.5P

STD

8

2.5P

STD

2.5P

STD

9

2.5P

STD

2.5P

STD

<ESTD REC>

 

D H

M

Relationship between the number of operational cameras and available “PPS” (pictures per second)

 

Number of

 

 

 

 

 

 

 

 

 

 

 

operational

# 1

# 2

# 3

# 4

# 5

# 6

# 7

# 8

# 9

 

PPS

 

cameras

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25P

25P

12.5P

12.5P

8.33P

8.33P

6.25P

6.25P

5P

 

SHORT

12.5P

12.5P

6.25P

6.25P

4.165P

4.165P

3.125P

3.125P

2.5P

 

 

 

 

8.333P

8.333P

4.167P

4.167P

2.777P

2.777P

2.083P

2.083P

1.667P

 

 

 

 

6.25P

6.25P

3.125P

3.125P

2.083P

2.083P

1.563P

1.563P

1.25P

 

 

 

 

5P

5P

2.5P

2.5P

1.666P

1.666P

1.25P

1.25P

1P

 

Recording

 

4.167P

4.167P

2.083P

2.083P

1.388P

1.388P

1.042P

1.042P

0.833P

 

 

interval

 

 

 

 

 

 

 

 

 

 

 

3.125P

3.125P

1.563P

1.563P

1.041P

1.041P

0.781P

0.781P

0.625P

 

 

 

 

2.5P

2.5P

1.25P

1.25P

0.833P

0.833P

0.625P

0.625P

0.5P

 

 

 

 

1P

1P

0.5P

0.5P

0.333P

0.333P

0.25P

0.25P

0.2P

 

 

 

 

 

 

LONG

0.5P

0.5P

0.25P

0.25P

0.167P

0.167P

0.125P

0.125P

0.1P

 

 

 

 

0.25P

0.25P

0.125P

0.125P

0.083P

0.083P

0.063P

0.063P

0.05P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.125P

0.125P

0.063P

0.063P

0.042P

0.042P

0.031P

0.031P

0.025P

 

 

 

 

 

 

 

 

 

 

 

 

 

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

 

•••••••••••••

22

Page 22
Image 22
Mitsubishi Electronics DX-TL950E operation manual SUPER, HIGH, STDSTANDARD, BASIC, Long, Short