<RECORD SETTINGS>

Settings concerning normal recording and alarm recording

This unit allows independent settings for normal recording and alarm recording. By this, more detailed settings are possible such as changing the recording intervals of the camera inputting the alarm signals while maintaining the normal recording settings as they are.

Certain settings and mode changes are limited during Alarm recording. Pressing the ALARM INTER- RUPT button halts additional alarm inputs, and lifts the limitations by stopping recording.

During recording, the setting in the <RECORD SETTING> screen cannot be changed.

When the cameras for recording are not input video signal, warning display of “NO SIGNAL” ap-

pears (for details, see “Warnings and CALL OUT output” pages 87,88).

Recording mode settings for normal recording and alarm recording

Setting of the camera number for alarm recording and emergency recording, the TRIGGER for alarm recording, the recording intervals and recording picture quality for nor- mal recording and alarm recording and whether to perform pre-alarm recording for alarm recording can be set here

(for normal recording, see “Basic manual recording” pages 21-23). Pre-alarm recording is a function to start re- cording before the ALARM IN terminal on the rear of the unit is grounded or motion is detected (for details concern-

ing pre-alarm recording, see page 64).

<RECORD SETTINGS>

 

 

>>ALARM SETTING

 

 

RECORD SETTING

 

5S

ALARM REC DURATION

PRE ALARM REC

( S )

S

MOTION DET REC

 

ALARM

1.Press the SET UP button } <SETTINGS> } Select “ALARM SETTING” in the <RECORD SETTINGS> screen and turn the SHUTTLE ring clockwise.

The <ALARM SETTING> screen appears.

<ALARM SETTING>

Camera selection during alarm recording

<ALARM

SETTING> >>ALARM CH

ALARM

RECORD CAMERA

TRIGGER

1

1 --------

EXT

2

-2-------

EXT

3

-- 3 ------

EXT

4

---4-----

EXT

5

----5----

EXT

6

-----6---

EXT

7

------ 7 --

EXT

8

------- 8 -

EXT

9

-------- 9

EXT

EMR

1 2 3 4 5 6 7 8 9

 

2.(When setting the camera selection during alarm recording

• • • )

Turn the JOG dial and move the cursor to camera selection item for alarm recording and turn the SHUTTLE ring clockwise.

The background of setting turns red and flashes.

• Setting ( default : “ALARM CH” )

ALARM CH” : Alarm recording is performed for only the cameras set for alarm recording and inputted with alarm signals. When there is input of alarm signals from multiple cameras, alarm recording is performed for all cameras containing alarm signals.

“ALARM PLUS” : Recording is performed in the frame speed set in “A-PPS” for the camera inputted with alarm signals during normal recording. All other cameras will be recording in the normal frame intervals.

“ALARM25” : Recording is performed so that normal recording and alarm recording each are up to max. 25 frames. With playback of a recording where an alarm recording has occurred during normal recording, there will be no recording interval display.

3.Display the desired item to set and turn the SHUTTLE ring clockwise.

The setting is confirmed and flashing stops.

4.(When setting “RECORD CAMERA” (the alarm recording camera) and “TRIGGER” • • • )

Turn the JOG dial to select the desired “ALARM” (alarm sensor input number) and turn the SHUTTLE ring clockwise.

The first item from the left side in the “RECORD CAMERA” setting display reverses in color.

The camera numbers are lined in order of the number from

1 ” to “ 9 ”. Multiple camera numbers can be selected for one alarm camera channel number.

When turn the JOG dial counterclockwise, the cam- era number setting or the TRIGGER setting will re-

verses in color in order such as 1 , EXT, 9 , 8 • • • .

5.Turn the JOG dial to display the desired camera number reversed in color and turn the SHUTTLE ring clockwise.

The background of setting turns red and flashes.

While the setting is flashing, the setting screen can- not be exited even when pressing the SET UP button.

6.Turn the JOG dial to display the desired setting and turn the SHUTTLE ring clockwise.

The setting is confirmed and flashing stops.

Two or more camera numbers can be chosen to one sensor input.

7.Turn the JOG dial clockwise to display “TRIGGER” setting reversed in color and turn the SHUTTLE ring clockwise.

The background of setting turns red and flashes.

8.Turn the JOG dial to display the desired setting and turn the SHUTTLE ring clockwise.

The setting is confirmed and flashing stops.

Setting of “TRIGGER” ( default : “EXT” )

EXT” : Alarm recording can only be started when the ALARM IN terminal is grounded.

“MD&EXT” : Alarm recording can be started when the ALARM IN terminal is grounded and the motion is detected simultaneously.

“MD/EXT” : When the ALARM IN terminal is grounded or motion is detected alarm recording is started.

“MD” : Alarm recording can only be started when the motion is detected.

ENGLISH

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Operations

41

Page 41
Image 41
Mitsubishi Electronics DX-TL950E Settings concerning normal recording and alarm recording, Ing pre-alarm recording, see