Mitsubishi Electronics DX-TL950E operation manual REC Mode C screen setting see

Models: DX-TL950E

1 90
Download 90 pages 24.16 Kb
Page 62
Image 62

Operation examples (continued)

7)<TIMER PROGRAM> screen setting ( see pages 44,45 ).

PROGRAM NO.1 : “SPL”, “08:00”, “15:00”, “A”, “OFF”.

PROGRAM NO.2 : “SPL”, “15:00”, “20:00”, “B”, “OFF”.

PROGRAM NO.3 : “SAT”, “08:00”, “17:00”, “B”, “OFF”.

PROGRAM NO.4 : “SUN”, “08:00”, “17:00”, “B”, “OFF”.

PROGRAM NO.5 : “HOL”, “08:00”, “17:00”, “B”, “OFF”.

SPL : “MON - FRI”.

<TIMER PROGRAM>

 

P2

1

DW

START END MODE

MD

SPL

08:00 15:00 A

OFF

2

SPL

15:00 20:00 B

OFF

3

SAT

08:00 17:00 B

OFF

4

SUN

08:00 17:00 B

OFF

5

HOL

08:00 17:00 B

OFF

6

---

--:-- --

:-- ----

-

7

---

--:-- --

:-- ----

-

8

---

--:-- --

:-- ----

-

>>SPL

MON-FRI

 

 

When completed with all settings above and after clear- ing the menu screen, press the TIMER button. The unit will switch to the timer mode.

Operation example 3

This example illustrates the procedure for using Pre-alarm recording, Alarm recording, Emergency recording with nor- mal recording in Timer record mode.

< Operation >

REC MODE C (pre-alarm recording, alarm recording and emergency recording with all cameras) is set to Monday ~ Friday from 08:00 to 15:00 and REC MODE D (pre-alarm recording, alarm recording and emergency recording with

camera number “1 ”, “2 ”, “3 ”, “7 ”, “8 ” and “9 ”) is set to 15:00 ~ 08:00 of the following day.

On weekends, REC MODE D (pre-alarm recording, alarm recording and emergency recording with camera number

1 ”, “2 ”, “3

”, “7 ”, “8 ” and “9

” ) is set to 08:00 ~

08:00 of the following day.

 

 

 

 

 

 

 

 

 

 

15:00

Next day

08:00

 

08:00

 

From Monday

 

 

 

 

 

 

 

 

 

REC MODE C

 

REC MODE D

 

to Friday

 

 

 

 

 

 

 

 

 

 

 

 

 

08:00

 

 

 

Next day

 

 

 

08:00

 

 

 

 

 

 

 

 

 

Saturday and

 

 

REC MODE D

 

Sunday

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

< Setting >

1)Set 1) ~ 3) of “Operation example “1 ” previous.

2)<REAR TERMINAL SETTINGS> screen setting ( see page 51).

EMERGENCY REC DURATION : “20M”.

<REAR

TERMINAL SETTINGS>

OFF

MODE

OUT

1

 

MODE

OUT

2

 

OFF

MODE

OUT

3

 

OFF

MODE

OUT

4

 

OFF

MODE

OUT

5

 

OFF

KEY SOUND

 

 

ON

BUZZER

 

 

OFF

REMAIN HDD

MAIN-10%

CALL OUT SETTINGS

 

20M

>>EMERGENCY REC DURATION

 

 

 

 

 

3)Set each item in the <MOTION DETECTION SET-

TINGS> screen for all cameras ( see pages 39,40).

<MOTION DETECTION

SETTINGS>

 

>>SELECTION CAMERA

NO.

1

DETECTION MASK SETTING

 

SENSITIVITY

HIGH••<<<LOW

MOTION THRESHOLD

 

5

TEST MODE

 

 

4)<TIMER PROGRAM SETTINGS> screen setting ( see pages 44-46).

SELECTED PATTERN : “P3”.

ALARM REC DURATION : “5M”.

<TIMER PROGRAM SETTINGS>

P3-SET

SELECTED PATTERN

HOLIDAY SETTING

 

REC MODE A

 

REC MODE B

 

REC MODE C

 

REC MODE D

5M

>>ALARM REC DURATION

5)<REC MODE C> screen setting ( see page 46).

MOTION DET REC : “ALARM”

PRE ALARM REC : Set desired pre-alaem recording time.

<REC MODE C>

 

 

ALARM SETTING

 

 

RECORD SETTING

( S )

S

PRE ALARM REC

>>MOTION DET REC

 

ALARM

6)<ALARM SETTING C> screen setting ( see page

All cameras ( “ 1 ” ~ “ 9 ” ).

TRIGGER : MD/EXT.

EMR : All cameras ( “ 1 ” ~ “ 9 ” ) is setting.

<ALARM SETTING C>

<ALARM SETTING C> ALARM CH

ALARM

RECORD CAMERA

TRIGGER

1

1 --------

MD/EXT

2

-2-------

MD/EXT

3

-- 3 ------

MD/EXT

4

---4-----

MD/EXT

5

----5----

MD/EXT

6

-----6---

MD/EXT

7

------ 7 --

MD/EXT

8

------- 8 -

MD/EXT

>>9

-------- 9

MD/EXT

EMR

1 2 3 4 5 6 7 8 9

 

7)<RECORD SETTING C> screen setting ( see page

Camera selection during alarm recording : “ALARM CH”.

All cameras ( “ 1 ” ~ “ 9 ” ).

PPS, GRADE, A-PPS, A-GRADE : Set desired interval and picture quality for each camera.

When “0S” is selected, the pre-alarm recording is inoperable.

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

•••••••••••••

62

Page 62
Image 62
Mitsubishi Electronics DX-TL950E operation manual REC Mode C screen setting see, Alarm Setting C screen setting see