Specifications

General

 

Rated Power Supply:

100 to 240 V AC, 50/60 Hz

Rated Input:

0.75 - 0.4 A (100-240 V)

Operating Temperature:

41 °F-104 °F (5 °C to 40 °C)

Relative Humidity:

Max. 80 (%)

Altitude:

Max. 2000 (m)

Dimensions:

424 (Width) x 361 (Depth) x 49 (Height) (mm)

Weight:

6.3 kg (with 2 HDD mounted)

Control terminals

 

CONT IN

Input terminal linked with the power supply of the recorder

CONT OUT

Output terminal linked with the power supply of the recorder

 

(CONT OUT is the through output of CONT IN.)

GND (Ground)

For grounding

TEMP ALM

Output terminal for detecting abnormal temperature (open collector output)

 

Active: “Low” level voltage output, Max. current 7 mA DC.

 

Non active: Open, Max. voltage 24 V DC.

FAN ALM

Output terminal for detecting fan error (open collector output)

 

Active: “Low” level voltage output, Max. current 7 mA DC.

 

Non active: Open, Max. voltage 24 V DC.

HDD ALM

Output terminal for detecting HDD error (open collector output)

 

Active: “Low” level voltage output, Max. current 7 mA DC.

 

Non active: Open, Max. voltage 24 V DC.

CONT IN

Reserved.

CONT OUT

Reserved.

EXTERNAL CONTROL:

When set to ON: Power is supplied to the HDD when 12V is applied to the input terminal linked with the power supply.

When set to OFF: Power is always supplied to the HDD.

Serial bus terminal

 

 

Serial bus terminal (2 terminals)

(Only DX-ZD6UE is connectable.)

Accessories:

USB2.0 cable

1

 

Control cable

1

 

Screws

8

 

User’s manual (this manual) 1

 

Power cord

3

Control input/output terminals and circuits

TEMP ALM terminal

FAN ALM terminal

HDD ALM terminal

• Output Circuit

Output terminal

GND terminal

<Interface circuit inside the unit>

Design and specifications are subject to change without notice.

20

Page 20
Image 20
Mitsubishi Electronics DX-ZD6UE operation manual Specifications, Control input/output terminals and circuits