3 - 37
3. SIGNALS AND WIRING
(3) Pulse train input interface DI-2
Provide a pulse train signal in the open collector or differential line driver system.
(a) Open collector system
1) Interface
Servo amplifier
P24L Max. input pulse
frequency 200kpps
Approx. 1.2kΩ
PP(NP)
Approx. 10mA
SG
SD
VDD
OPC
P24G
24VDC
2) Conditions of the input pulse
0.9
0.1
tc tHL
tc tLH tF
tLH = tHL < 0.2µs
tc > 2µs
tF > 3µs
PP
NP