3 - 45
3. SIGNALS AND WIRING
3.9 Grounding
WARNING
yGround the servo amplifier and servo motor securely.
yTo prevent an electric shock, always connect the earth terminal (E) of the servo
amplifier to the earth (E) of the control box (refer to (2) of this section for the f itting
method of the earth terminal).
(1) Connection diagram
The servo amplifier switches the power transistor on-off to supply power to the servo motor. Depending
on the wiring and ground cablerouting, the servo amplifier may be affected by the switching noise (due
to di/dt and dv/dt) of the transistor. To prevent such a fault, re fer to the fo llow ing diag ram an d alw ays
ground.
To conform to the EMC Directive, refer to the EMC INSTALLATION GUIDELINES (IB(NA)67310).
P24M
P24G
P24L
Servo motor
CN1A CN1B
Earth (E)
24VDC
Circuit
protector
Control box
Servo amplifier
Outer
box
Programmable
controller
RA