The table below shows the role of Exclusive LEV and Receiver LEV in each operation mode.

 

Circulation

Capacity

Discharge

High

wEvaporation

 

Amount

Temperature

Pressure

Temperature

 

Distribution

 

Control

Protection

Protection

Protection

 

 

COOL

Exclusive LEV

 

 

 

 

Receiver LEV

 

 

 

 

 

 

 

 

 

HEAT

Exclusive LEV

 

 

 

 

Receiver LEV

 

 

 

 

 

 

 

 

 

Indoor heat

Exclusive

exchanger

LEV

(MXZ-3A)

Outdoor heat exchanger

Receiver

Receiver

LEV

wIn COOL mode, the two indoor coil thermistor (one main and one sub) sense temperature ununiformity (super heat) at the heat exchanger, and when temperature difference have developed, the indoor coil thermistors adjust LEV opening to dimin- ish the super heat.This action is called Evaporation Temperature Protection.

The opening pulse of the Receiver LEV is fixed to the standard No.3 in cooling operation, and so is that of each Exclusive LEV in heating operation.

However the opening pulse will be changed to the standard No.4 or No.5 when the discharge temperature protection or high- pressure protection is working.

In addition to that, it will also be changed to standard No.2 or No.1 when the opening pulse of the each Exclusive LEV becomes 100 pulse or less in cooling operation or so does that of Receiver LEV in heating operation.

<MXZ-2A>

 

 

 

 

 

 

Number of

 

 

LEV opening (pulse)

 

 

operating

 

COOL

 

 

HEAT

 

indoor units

 

 

 

 

Standard No.

1 unit

 

2 units

1 unit

 

2 units

1

200

 

150

120

 

120

2

300

 

320

140

 

140

3

400

 

360

160

 

160

4

450

 

410

220

 

220

5

500

 

500

280

 

280

<MXZ-3A>

 

 

 

 

 

 

Number of

 

 

LEV opening (pulse)

 

 

operating

 

COOL

 

 

HEAT

 

indoor units

 

 

 

 

Standard No.

1 unit

2 units

3 units

1 unit

2 units

3 units

1

150

250

250

250

250

250

2

250

320

320

300

300

300

3

350

360

370

450

380

380

4

400

410

420

460

400

390

5

450

460

470

470

450

440

23

Page 23
Image 23
Mitsubishi Electronics MUY-ANA, MS-AWA, MUZ-ANA, MU-AWA, MSY-ANA MXZ-2A, MXZ-3A, Outdoor heat exchanger Receiver Receiver LEV