Mitsubishi Electronics MU-AWA Outdoor Fan Motor Control, Auto Vane Operation, Horizontal vane

Models: MUY-ANA MSY-ANA MS-AWA MUZ-ANA MXZ-ANA MSZ-ANA MU-AWA

1 28
Download 28 pages 7.08 Kb
Page 10
Image 10
2-5. OUTDOOR FAN MOTOR CONTROL

(3)Indoor fan control/ Vane control

As the indoor fan speed and the horizontal vane position depend on the selected operation mode, when the operation mode changes over, they change to the exclusive ones.

2-5. OUTDOOR FAN MOTOR CONTROL

Fan speed is switched according to the compressor frequency.

Fan speed

High

Low

Down Up

Min. Compressor frequency Max.

<Relation between compressor frequency and fan speed.>

 

 

Compressor frequency (Hz)

Mode

Fan speed

MUZ-A09/12/15/17/24

 

 

MUY-A15/17/24

 

 

 

COOL

Up

44

 

 

Down

33

 

 

 

 

HEAT

Up

44

(MUZ)

Down

33

 

 

 

2-6. AUTO VANE OPERATION

1. Horizontal vane

(1) Cold air prevention in HEAT operation. (MUZ)

When any of the following conditions occurs in HEAT operation, the vane angle changes to Horizontal position automati- cally to prevent cold air blowing on users.

Compressor is not operating.

Defrosting is performed.

Indoor coil thermistor RT12 temperature does not exceed 102ºF within about 3 minutes after compressor starts.

NOTE: When 2 or more indoor units are operated with multi outdoor unit, even if any indoor unit turns thermostat off, this control doesn’t work in the indoor unit.

(2)ECONO COOL ( 2-6. AUTO VANE OPERATIONManual background ) operation (ECONOmical operation)

When ECONO COOL button is pressed in COOL mode, set temperature is automatically set 3.6 degrees higher than that in COOL mode.

Also the horizontal vane swings in various cycle according to the temperature of indoor heat exchanger (RT12). SWING operation makes you feel cooler than set temperature. So, even though the set temperature is higher than that in COOL mode, the air conditioner can keep comfort. As a result, energy can be saved.

ECONO COOL operation is cancelled when ECONO COOL button is pressed once again or VANE CONTROL button is pressed or change to other operation mode.

10

Page 10
Image 10
Mitsubishi Electronics MU-AWA, MS-AWA, MUZ-ANA, MUY-ANA manual Outdoor Fan Motor Control, Auto Vane Operation, Horizontal vane