2-4. PIPE FORMING AND DRAIN PIPING

2-4-1. PIPE FORMING

Place the drain hose below the refrigerant piping.

Make sure that the drain hose is not crowded or bent.

Do not pull the hose when applying the tape.

When the drain hose passes the room, be sure to wrap it with insulation material

¿HOGVXSSOLHG 

Note:

Make sure not to damage the cover of refrigerant pipe when attaching it back on with screws.

Left or left-rear piping

Note:

Be sure to reattach the drain hose and the drain cap if the piping is being installed on left or bottom left of unit, otherwise, water could drip down from the drain hose.

 3ODFHWKHUHIULJHUDQWSLSLQJDQGWKHGUDLQKRVHWRJHWKHUWKHQ¿UPO\DSSO\IHOWWDSH   from the end.

Felt tape (7) overlap width should be 1/3 the tape width. Use a bandage stopper at the end of felt tape (7).

2)Pull out the drain cap at the back right of the indoor unit. (Fig. 1)

Hold the convex section at the end and pull the drain cap.

3)Pull out the drain hose at the back left of the indoor unit. (Fig. 2)

Hold the claw marked by the arrows and pull out the drain hose forward.

4)Put the drain cap into the section to which the drain hose is to be attached at the rear of the indoor unit. (Fig. 3)

Insert a screwdriver into the hole on the cap and insert the cap fully into the drain pan.

5)Insert the drain hose fully into the drain pan at the back right of the indoor unit. (Fig. 4)

Check if the hose is hooked securely to the projection of its inserting part at the drain pan.

6)Insert the drain hose into wall hole sleeve (C), and attach the upper part of indoor unit onto the installation plate (1). Then, shift the indoor unit completely to the left to make placing the piping in the back of the unit easier.

7)Cut out a piece of cardboard from the shipping box, roll it up, hook it onto the back rib, and use it as a spacer to lift the indoor unit. (Fig. 5)

8)Connect the refrigerant piping with the extension pipe (B).

9)Attach the lower part of the indoor unit into the installation plate (1).

Rear or bottom piping  3ODFHWKHUHIULJHUDQWSLSLQJDQGWKHGUDLQKRVHWRJHWKHUWKHQ¿UPO\DSSO\SLSLQJWDSH

(G) from the end.

2)Insert the piping and the drain hose into the wall hole sleeve (C), and attach the up- per part of the indoor unit on the installation plate (1).

3)Check if the indoor unit is attached securely on the installation plate (1) by moving the unit to left and right.

4)Attach the lower part of the indoor unit into the installation plate (1).

Right piping

Note:

Before performing the following, make sure that wiring is completed, and the conduit cover is installed. (Refer to 2-3.)

1)Place the refrigerant piping and the drain hose together, shift them to left side of the

XQLWDQGWKHQ¿UPO\DSSO\SLSLQJWDSH * IURPWKHHQG

2)Insert the piping and the drain hose into the wall hole sleeve (C), and attach the up- per part of the indoor unit on the installation plate (1).

3)Check if the indoor unit is attached securely on the installation plate (1) by moving the unit to left and right.

4)Attach the lower part of the indoor unit into the installation plate (1).

2-4-2. DRAIN PIPING

If the extension drain hose has to pass through a room, be sure to wrap it with insu-

ODWLRQ ¿HOGVXSSOLHG 

The drain hose should point downward for easy drain. (Fig. 1)

‡ ,I WKH GUDLQ KRVH SURYLGHG ZLWK WKH LQGRRU XQLW LV WRR VKRUW FRQQHFW LW ZLWK D ¿HOG supplied drain hose (I). (Fig. 2)

When connecting the drain hose to a hard vinyl chloride pipe, be sure to insert it se- curely into the pipe. (Fig. 3)

Liquid pipe

Gas pipe

Indoor/outdoor unit connecting wire (A)

Felt tape (7)

Piping tape (G)

Felt tape (7)

Piping tape (G)

Remove panel for piping

 

on left side of unit.

Drain cap

 

Drain hose

Fig. 1

Fig. 2

 

Drain hose

Drain cap

 

Fig. 3

Fig. 4

Fig. 5

Remove panel for piping on bottom side of unit

Remove panel for piping on right side of unit

To the left

 

Drain

 

Drain hose

 

hose

27-9/16 in.

Hard vinyl chloride pipe

Downward

 

I.D. 1-3/16 in.

 

(70 cm)

 

(30 mm)

slope

Soft hose I.D.

or more

 

 

 

Insert

 

19/32 in.

 

 

(15 mm)

Different

securely

 

 

 

 

 

diameter joint

 

Fig. 1

Fig. 2

 

Fig. 3

Do not make drain piping as shown below.

 

Do not raise

Accumulated

 

 

 

drain water

 

 

 

Air

 

Water

Water

Waving

Water

leakage

leakage

leakage

 

At least

Tip of drain

1-31/32 in.

(50 mm)

hose dipped

gap

in water

 

Ditch

 

Page 5
Image 5
Mitsubishi Electronics MSZ-FD09/12NA Pipe Forming and Drain Piping, Left or left-rear piping, Right piping

MSZ-FD09/12NA specifications

Mitsubishi Electronics has been a leader in the HVAC industry for decades, and the MSZ-FD09/12NA is a testament to their commitment to innovation and efficiency. This wall-mounted indoor unit is part of Mitsubishi's compact and stylish FD Series, catering to both residential and commercial applications.

One of the standout features of the MSZ-FD09/12NA is its advanced energy efficiency. With a high seasonal energy efficiency ratio (SEER) rating, this model operates quietly while consuming minimal power, making it an environmentally friendly choice that can significantly reduce electricity bills. This level of efficiency is particularly beneficial for users looking to maintain a sustainable lifestyle.

The MSZ-FD09/12NA incorporates Mitsubishi’s INVERTER technology, allowing for continuous adjustments to the compressor speed. This results in more precise temperature control, maintaining comfort levels without the energy spikes commonly associated with traditional cooling and heating systems. This technology not only enhances comfort but also extends the lifespan of the unit through reduced wear and tear.

Enhanced air filtration is another important characteristic of the MSZ-FD09/12NA. The unit comes equipped with a multi-stage filtration system that includes a special anti-allergen filter. This feature is particularly beneficial for allergy sufferers, as it captures dust, pollen, and other airborne particles, ensuring cleaner air in the household or workspace.

In terms of design, the MSZ-FD09/12NA is sleek and unobtrusive, blending seamlessly with modern interiors. Its compact size doesn’t compromise its performance, making it an ideal choice for rooms with limited space. Furthermore, the unit operates quietly, with noise levels as low as 19 decibels, allowing for a peaceful environment free from disruptive sounds.

Control options for the MSZ-FD09/12NA are versatile. Users can utilize a wireless remote control for convenience or connect the unit to a centralized smart home system for enhanced functionality. This capability allows for temperature adjustments from anywhere in the home, offering significant flexibility for homeowners.

Overall, the Mitsubishi MSZ-FD09/12NA stands out in the crowded HVAC market for its combination of energy efficiency, advanced technologies, and user-friendly features. Whether it's for residential comfort or commercial applications, this unit promises consistent performance and reliability, ensuring that it meets the diverse needs of modern consumers.