SLIDE SWITCH

3-3. PIPE CONNECTION

‡ )DVWHQÀDUHQXWZLWKDWRUTXHZUHQFKDVVSHFL¿HGLQWKHWDEOH UHIHUWR 

‡ :KHQIDVWHQHGWRRWLJKWÀDUHQXWPD\HYHQWXDOO\EUHDNDQGFDXVHUHIULJHUDQWOHDNDJH

Indoor unit connection

Connect both liquid and gas pipings to indoor unit.

• Apply a thin coat of refrigerant oil (J) on the seat surface of pipe.

‡ 7RFRQQHFW¿UVWDOLJQWKHFHQWHUWKHQWLJKWHQWKH¿UVWWRWXUQVRIÀDUHQXW

Use tightening torque table above as a guideline for indoor unit side joints, and tighten

XVLQJWZRZUHQFKHV([FHVVLYHWLJKWHQLQJGDPDJHVWKHÀDUHVHFWLRQ

Outdoor unit connection

Connect pipes to stop valve pipe joint of the outdoor unit following the same procedure detailed in Indoor unit connection.

• For tightening, use a torque wrench or spanner.

3-4. INSULATION AND TAPING

1)Cover piping joints with pipe cover.

2)For outdoor unit side, insulate the piping, including valves.

3)Apply piping tape (G) starting from the connection on the outdoor unit.

When piping has to be installed through a ceiling, closet or where the temperature

DQGKXPLGLW\DUHKLJKXVHDGGLWLRQDO¿HOGVXSSOLHGLQVXODWLRQWRSUHYHQWFRQGHQVD- tion.

4. PURGING PROCEDURES, LEAK TEST, AND TEST RUN

4-1. PURGING PROCEDURES AND LEAK TEST

1)Remove service port cap of stop valve on the side of the outdoor unit gas pipe.

2)Connect gauge manifold valve and vacuum pump to service port of stop valve on the gas pipe side of the outdoor unit.

4-2. TEST RUN

1)

Insert power supply plug into the power outlet and/or turn

 

on the breaker.

2)

Press the E.O. SW once. Test run will be performed for

 

30 minutes. If the power lamp blinks every 0.5 seconds,

 

inspect the indoor/outdoor unit connecting wire (A). After

 

the test run, emergency COOL mode (75ºF [24ºC] COOL)

*4 to 5 turns

*Close

*Open

Stop valve cap (Torque 19.6 to

29.4N•m, 200

WRNJIƒFP

–0.101 MPa (–30 in.Hg [–760 mHg])

Stop valve for LIQUID

Compound pressure gauge (for R410A)

Pressure gauge (for R410A)

Gauge manifold valve (for R410A)

will start.

3) To stop operation, press the E.O. SW several times until

all LED lamps turn off. Refer to operating instructions for

details.

Checking the remote (infrared) signal reception

Emergency operation switch (E.O. SW)

Hexagonal wrench

Service port cap (Torque 13.7 to

17.7N•m, 140 to

180 kgf•cm)

Handle

Low

Stop valve for

GAS

Adapter for pre- venting the back

ÀRZ

Handle High

Charge hose (for R410A)

Vacuum pump (or the vacuum pump with the function to SUHYHQWWKHEDFNÀRZ

Press the ON/OFF button on the remote controller and listen for an audible indicator from the indoor unit. Press the ON/OFF button again to turn the air conditioner off.

Once the compressor stops, the restart preventive device operates so the compressor will not operate for 3 minutes to protect the air conditioner.

4-3. AUTO RESTART FUNCTION

This product is equipped with an auto restart function. When the power supply is cut off during operation, such as during blackouts, the function automatically starts operation in the previous setting once the power supply is resumed. (Refer to the operating instructions for details.)

Precautions when using the control valve

Service port

A

Control valve

Open

Close

Charge hose

Body

When attaching the control valve to the service port, valve core may deform or loosen if excess pressure is applied. This may cause gas leak.

When attaching the control valve to the service port, make sure that the valve core is in closed position, and then tighten part A. Do not tighten part A or turn the body when valve core is in open position.

Caution:

After test run or remote signal reception check, turn off the unit with the E.O. SW or the remote controller before turning off the power supply. If this procedure is not per-

formed, the unit will automatically begin operation when power supply is resumed.

To the user

After installing the unit, explain to the user about auto restart function.

If auto restart function is unnecessary, it can be deactivated. Consult the service rep- resentative to deactivate the function. Refer to the service manual for details.

4-4. REMOTE CONTROLLER SETTING

Set the slide switch of the remote controller according to where the indoor unit is installed in the area. If the switch is not set correctly, the air conditioner may not function properly.

3)Run the vacuum pump 15 minutes or more.

4)Check the vacuum with the gauge manifold valve, then close it and shut off the vacuum pump.

5)Leave as it is for one or two minutes. Make sure pointer gauge manifold valve remains

LQ WKH VDPH SRVLWLRQ &RQ¿UP WKDW SUHVVXUH JDXJH VKRZV ± 03D >*DXJH@ ± in.Hg [–760 mmHg]).

6)Quickly remove gauge manifold valve from service port of stop valve.

7)After refrigerant pipes are connected and evacuated, fully open all stop valves on both sides of gas pipe and liquid pipe. Operating the unit without fully opening the valves lowers the performance and causes problems.

8)Refer to 1-3. SPECIFICATIONS, and charge the prescribed amount of refrigerant if needed. Be sure to charge slowly with liquid refrigerant. Otherwise, composition of the refrigerant in the system may be changed and affect performance of the air conditioner.

9)Tighten cap of service port.

10)Conduct a leak test

Location of unit in area:

Left: Distance to objects (wall, cabinet, etc.) is less

 

 

(Left) (Center)(Right)

than 19-11/16 in. (50 cm) to the left

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Center: Distance to objects (wall, cabinet, etc.) is

 

 

 

 

 

 

 

 

 

 

 

more than 19-11/16 in. (50 cm) to the left and right

 

 

 

 

 

 

 

 

 

 

 

Right: Distance to objects (wall, cabinet, etc.) is less

 

 

 

 

 

 

 

 

 

 

 

than 19-11/16 in. (50 cm) to the right

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) Remove the front lid.

2) Set the slide switch according to the installed position of the indoor unit.

3) Insert two (AAA) batteries.

4) Reattach the front lid.

5) Press the RESET button gently using a thin instrument.

Installation posi-

Left

Center

Right

RESET

button

tion

 

 

 

 

Slide switch

 

 

 

 

Remote controller

 

 

 

 

display

 

 

 

 

4-5. EXPLANATION TO THE USER

Using the OPERATING INSTRUCTIONS, explain to the user how to use the air condition-

HU WKHUHPRWHFRQWUROOHUUHPRYLQJWKHDLU¿OWHUVSODFLQJRUUHPRYLQJWKHUHPRWHFRQWUROOHU from the remote controller holder, cleaning methods, precautions for operation, etc.)

Recommend that the user read the OPERATING INSTRUCTIONS carefully.

Page 7
Image 7
Mitsubishi Electronics MSZ-FD09/12NA installation manual Purging PROCEDURES, Leak TEST, and Test RUN

MSZ-FD09/12NA specifications

Mitsubishi Electronics has been a leader in the HVAC industry for decades, and the MSZ-FD09/12NA is a testament to their commitment to innovation and efficiency. This wall-mounted indoor unit is part of Mitsubishi's compact and stylish FD Series, catering to both residential and commercial applications.

One of the standout features of the MSZ-FD09/12NA is its advanced energy efficiency. With a high seasonal energy efficiency ratio (SEER) rating, this model operates quietly while consuming minimal power, making it an environmentally friendly choice that can significantly reduce electricity bills. This level of efficiency is particularly beneficial for users looking to maintain a sustainable lifestyle.

The MSZ-FD09/12NA incorporates Mitsubishi’s INVERTER technology, allowing for continuous adjustments to the compressor speed. This results in more precise temperature control, maintaining comfort levels without the energy spikes commonly associated with traditional cooling and heating systems. This technology not only enhances comfort but also extends the lifespan of the unit through reduced wear and tear.

Enhanced air filtration is another important characteristic of the MSZ-FD09/12NA. The unit comes equipped with a multi-stage filtration system that includes a special anti-allergen filter. This feature is particularly beneficial for allergy sufferers, as it captures dust, pollen, and other airborne particles, ensuring cleaner air in the household or workspace.

In terms of design, the MSZ-FD09/12NA is sleek and unobtrusive, blending seamlessly with modern interiors. Its compact size doesn’t compromise its performance, making it an ideal choice for rooms with limited space. Furthermore, the unit operates quietly, with noise levels as low as 19 decibels, allowing for a peaceful environment free from disruptive sounds.

Control options for the MSZ-FD09/12NA are versatile. Users can utilize a wireless remote control for convenience or connect the unit to a centralized smart home system for enhanced functionality. This capability allows for temperature adjustments from anywhere in the home, offering significant flexibility for homeowners.

Overall, the Mitsubishi MSZ-FD09/12NA stands out in the crowded HVAC market for its combination of energy efficiency, advanced technologies, and user-friendly features. Whether it's for residential comfort or commercial applications, this unit promises consistent performance and reliability, ensuring that it meets the diverse needs of modern consumers.