York THGD18 THRU 60 YTG-B-0508, Johnson Controls Unitary Products, Outdoor Unit, Indoor Coil3,4

Models: THGD18 THRU 60

1 30
Download 30 pages 54.87 Kb
Page 3
Image 3
Outdoor Unit

397763-YTG-B-0508

Additional R-410A Charge / Orifice Size for Various Matched Systems

Outdoor Unit

THGD18

THGD24

THGD30

THGD36

THGD42

THGD48

THGD60

S41S1

S41S1

S41S1

S41S1

S41S1

S41S1

S41S1

 

 

 

 

Required Orifice or TXV 1,2

1TVM0901

1TVM0903

1TVM0903

1TVM0904

1TVM0904

1TVM0905

1TVM0906

Factory Charge, lbs-oz

6 - 5

8 - 7

9 - 12

9 - 15

9 - 12

13 - 9

13 - 6

 

 

 

 

 

 

 

 

Indoor Coil3,4

 

 

Additional Charge, Oz

 

 

FC/MC/PC/UC18AB

0

FC/MC/PC/UC24AB

+ 4

0

FC/MC/PC30AB

0

FC/MC/PC32A

0

0

FC/MC/PC35BC

0

0

FC/MC/PC37A

0

0

FC/MC/PC43BC

0

0

FC/MC/PC/UC48CD

+ 10

0

0

FC/MC/PC/UC60CD

0

0

FC/MC62D

 

 

+ 12

0

HC18A

 

 

+ 1

HC30A

 

 

+ 10

0

HC36B

 

 

0

0

HC42

 

 

0

0

0

HC60

 

 

0

0

HD24

 

 

+ 14

HD36

 

 

+ 2

HD48

 

 

+ 8

+ 8

HD60

 

 

0

+ 7

AHP18

 

 

0

AHP30

 

 

0

AHP36

 

 

0

0

AHP/SHP48

 

 

0

0

AHP/SHP60

 

 

0

AV24

 

 

+ 3

0

AV36

 

 

6

0

0

AV/SV48

 

 

0

0

AV/SV60

 

 

0

F4FP24

 

 

 

0

 

See Caution below

 

 

 

 

 

 

 

 

 

 

 

F4FP30

 

 

 

0

 

See Caution below

 

 

 

 

 

 

 

 

 

 

 

F4FP40

 

 

 

0

 

See Caution below

 

 

 

 

 

 

 

 

 

 

 

F4FP45

 

 

 

0

0

 

See Caution below

 

 

 

 

 

 

 

 

 

 

 

F5FP48

 

 

 

0

0

 

See Caution below

 

 

 

 

 

 

 

 

 

 

 

F4FV60

 

 

 

0

 

See Caution below

 

 

 

 

 

 

 

 

 

 

 

F5FP60

 

 

 

0

 

See Caution below

FOOTNOTES:

1.For applications requiring a TXV use 1TVM900 series kit.

2.Approved orifice shipped with outdoor unit.

3.Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.

4.PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.

PROCEDURES:

1.Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnect- ing line tubing.

2.Verify the TXV or orifice and additional charge required for specific evaporator coil in the system using the above table.

3.Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.

4.For TXV match charge weight needs to be weighed in for specififc coil match and lineset length.

5.Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evapo- rator + adder for line set.

F*FP Air Handlers come with a factory installed R-22 TXV which MUST BE CHANGED OUT to R-410A TXV or an orifice for proper opera- tion. If the TXV is not changed out system damage will occur.

Johnson Controls Unitary Products

3

Page 3
Image 3
York THGD18 THRU 60 YTG-B-0508, Johnson Controls Unitary Products, Outdoor Unit, Required Orifice or TXV 1,2, Footnotes