COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils

 

 

FURNACE**

 

COIL

 

 

COOLING

 

 

UNIT MODEL

CFM RANGE

 

 

RATED

NET MBH

SEER1

 

 

W

MODEL

EER

 

(Min.-max.)

 

CFM

 

 

 

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

450

- 750

 

14,17

FC/MC/PC18

600

17.0

12.6

13.00

11.00

 

450

- 750

 

14,17

FC/MC/PC24

600

17.0

12.9

13.50

11.00

THGD18S41S1

450

- 750

 

14

HC18

600

17.0

12.6

13.00

11.00

 

450

- 750

 

14

HC30

600

17.0

12.8

13.00

11.00

 

450

- 750

 

14

HD24

600

17.0

13.0

13.50

11.00

 

600 - 1000

 

14,17

FC/MC/PC24

800

23.0

17.1

13.00

11.00

 

600 - 1000

 

14,17

FC/MC/PC30

800

23.0

17.2

13.00

11.00

 

600 - 1000

 

14

FC/MC/PC32

800

23.0

17.5

13.00

11.00

THGD24S41S1

600 - 1000

 

17,21

FC/MC/PC35

800

23.0

17.5

13.00

11.00

 

600 - 1000

 

14

HC30

800

23.0

17.2

13.00

11.00

 

600 - 1000

 

17

HC36

800

23.0

17.5

13.00

11.00

 

600 - 1000

 

14,17

HD36

800

23.0

16.4

13.00

11.00

 

800 - 1200

 

14

FC/MC/PC32

1000

29.0

23.2

13.00

11.00

 

800 - 1200

 

17,21

FC/MC/PC35

1000

29.0

23.2

13.00

11.00

 

800 - 1200

 

14

FC/MC/PC37

1000

29.0

23.4

13.00

11.00

THGD30S41S1

800 - 1200

 

17,21

FC/MC/PC43

1000

29.0

23.4

13.00

11.00

 

800 - 1200

 

17

HC36

1000

29.0

23.2

13.00

11.00

 

800 - 1200

 

21

HC42

1000

29.0

23.4

13.00

11.00

 

800 - 1200

 

21,24

HD48

1000

29.0

23.4

13.00

11.00

 

1000

- 1400

 

14

FC/MC/PC37

1200

35.0

26.6

13.00

11.00

 

1000

- 1400

 

17,21

FC/MC/PC43

1200

35.0

26.8

13.00

11.00

THGD36S41S1

1000

- 1400

 

21,24

FC/MC/PC48

1200

35.0

27.0

13.00

11.00

 

1000

- 1400

 

21

HC42

1200

35.0

26.8

13.00

11.00

 

1000

- 1400

 

21,24

HD48

1200

35.0

26.8

13.00

11.00

 

1200

- 1600

 

21,24

FC/MC/PC48

1400

41.5

31.4

13.00

11.00

 

1200

- 1600

 

21,24

FC/MC/PC60

1400

41.0

31.2

13.00

11.00

THGD42S41S1

1200

- 1600

 

21

HC42

1400

41.0

31.2

13.00

11.00

 

1200

- 1600

 

24

HC60

1400

41.0

31.2

13.00

11.00

 

1200

- 1600

 

21,24

HD60

1400

41.5

31.4

13.00

11.00

 

1400

- 1800

 

21,24

FC/MC/PC48

1600

47.0

35.2

13.00

11.00

 

1400

- 1800

 

21,24

FC/MC/PC60

1600

47.0

35.6

13.00

11.00

THGD48S41S1

1400

- 1800

 

24

HC60

1600

47.0

35.6

13.00

11.00

 

1400

- 1800

 

21,24

HD60

1600

47.0

35.4

13.00

11.00

 

1400

- 1800

 

21,24

MC62

1600

47.0

35.6

13.00

11.00

THGD60S41S1

1600

- 2000

 

21,24

MC62

1800

54.0

42.5

13.00

11.00

1.Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up.