ACCESSORIES

397763-YTG-B-0508

ACCESSORIES

Refer to Price Manual for specific model numbers.

Start Assist Kit (2SA067*) - May be required on 42, 48, 60 models. Models 18, 24, 30, 36 have been factory installed.

Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied.

Hard Start Kits - Provides required starting torque for use with Thermal Expansion Valve Kit.

Low Temperature Cutout (2LT06700224) - Prevents heat pump operation below -10°F ambient temperature.

Compressor Blanket - Designed to further reduce the nor- mal operating sound.

Add-on Fossil Fuel Control - Interface controls for use with gas, oil furnaces and the heat pump system are available.

Thermal Expansion Valve Kit - 1TVM900 Series TXV kit used to improve system performance.

Outdoor Thermostat (2TD06700124) - Provides additional staging of supplemental electric heat.

TYPICAL INSTALLATION

Room Thermostats - A wide selection of matching thermo- stats is available to provide features required for any installa- tion.

2H/1C, manual changeover electronic non-programmable thermostat.

3H/2C, non-programmable digital thermostat.

3H/2C, auto/manual changeover, electronic programmable, 7-day, hardwire thermostat.

*For the most current accessory information, refer to the price book or consult factory.

SOUND POWER RATINGS

UNIT MODEL

 

(dBA)*

 

 

 

 

Cooling

 

Heating

018

TBD

 

TBD

024

TBD

 

TBD

030

TBD

 

TBD

036

TBD

 

TBD

042

TBD

 

TBD

048

TBD

 

TBD

060

TBD

 

TBD

* Rated in accordance with ARI 270-95 Standards.

 

MINIMUM 24” SERVICE

 

48” OVERHEAD

ACCESS CLEARANCE

THERMOSTAT

ON ONE SIDE

CLEARANCE

 

 

 

 

WEATHERPROOF

 

 

DISCONNECT

 

 

SWITCH

 

 

 

NEC CLASS 1 WIRING

10” CLEARANCE

 

TO FURNACE OR

AROUND PERIMETER

 

AIR HANDLER

 

 

TERMINAL BLOCK

 

 

NEC CLASS 2 WIRING

 

 

TO INDOOR COIL

NOTE:

 

 

ALL OUTDOOR WIRING

CONTROL

 

MUST BE WEATHERPROOF.

 

ACCESS

SEAL OPENING(S) WITH

 

 

PANEL

PERMAGUM OR EQUIVALENT

TYPICAL FIELD WIRING

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

 

THERMOSTAT

 

 

INDOOR UNIT

OUTDOOR UNIT

 

 

 

 

 

 

LOW VOLTAGE TERMINAL BLOCK 3,4

DEFROST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN AIR HANDLER WITH ELECTRIC HEAT

CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

R

 

RED

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B or C

 

 

C

 

 

BLK

C

 

 

CONTACTOR

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

Y

 

YEL

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

O

 

 

ORG

 

O

 

 

 

T2

 

T1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

 

 

W2

 

WHT

W

 

 

 

 

M

 

 

 

 

GND.

L or X

 

 

 

 

 

PUR

X/L

 

 

 

 

L2

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCREW

 

G

 

 

 

G

 

 

BRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W1/66

 

 

 

 

 

 

 

 

 

 

 

 

T 2

 

1 FIELD

 

W1

 

 

5GRY

CC

 

 

 

 

 

 

 

 

 

 

 

 

 

E 2

 

INSTALLED

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JUMPER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1JUMPER TERMINALS E AND W TO HEAT

 

DEHUMIDIFICATION CONTROL CONNECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON FIRST STAGE DURING EMERGENCY HEAT.

(Humidistat* Jumper must be removed)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TERMINAL NOT USED ON ALL THERMOSTATS.

 

 

GND. LUG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER WIRING

POWER WIRING

 

 

CIRCUIT

 

 

 

 

 

208/230-1-60

 

 

24V CONTROL WIRING

 

 

 

 

 

 

 

 

 

 

230-1-50

 

 

 

 

 

BREAKER***

 

 

 

 

 

 

 

 

 

 

 

(NEC CLASS 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3CHECK THE LOW VOLTAGE TERMINAL BLOCK ON THE INDOOR UNIT FOR THE ACTUAL ARRANGEMENT OF THE TERMINALS.

4 CONNECT POWER WIRING TO TERMINAL BLOCK 3TB ON UNITS WITHOUT ELECTRIC HEAT OR CIRCUIT BREAKER.

5GRAY FOR USE WITH OPTIONAL OUTDOOR THERMOSTAT KITS.