York THGD18 THRU 60 warranty FC/MC/PC/UC1

Models: THGD18 THRU 60

1 30
Download 30 pages 54.87 Kb
Page 12
Image 12

397763-YTG-B-0508

HEATING PERFORMANCE - Upflow, Downflow, and Horizontal Furnaces and Coils

UNIT

COIL1

 

 

 

ARI HEATING2

 

 

 

MODEL*

MODEL

 

47°F

 

 

 

 

17°F

 

HSPF

 

 

MBH

COP

KW

 

MBH

 

COP

KW

STD

 

FC/MC/PC/UC1

17.0

3.32

1.50

 

12.7

 

3.00

1.24

7.70

 

FC/MC/PC/UC2

17.0

3.44

1.45

 

10.4

 

2.60

1.17

7.70

THGD18S41S1

HC18

17.0

3.32

1.50

 

12.7

 

3.00

1.24

7.70

 

HC30

17.0

3.38

1.47

 

10.4

 

2.60

1.17

7.70

 

HD24

16.6

3.16

1.54

 

12.8

 

3.00

1.25

7.70

 

FC/MC/PC24

23.2

3.40

2.00

 

12.6

 

2.24

1.65

7.70

 

FC/MC/PC30

23.2

3.40

2.00

 

12.6

 

2.24

1.65

7.70

 

FC/MC/PC32

23.2

3.40

2.00

 

12.6

 

2.24

1.65

7.70

THGD24S41S1

FC/MC/PC35

23.2

3.40

2.00

 

12.6

 

2.24

1.65

7.70

 

HC30

23.0

3.40

1.98

 

12.6

 

2.24

1.65

7.70

 

HC36

23.2

3.40

2.00

 

12.6

 

2.24

1.65

7.70

 

HD36

23.2

3.40

2.00

 

12.6

 

2.24

1.65

7.70

 

FC/MC/PC32

28.0

3.34

2.46

 

16.4

 

2.28

2.11

7.70

 

FC/MC/PC35

28.0

3.34

2.46

 

16.4

 

2.30

2.09

7.70

 

FC/MC/PC37

28.2

3.40

2.43

 

16.6

 

2.32

2.10

7.70

THGD30S41S1

FC/MC/PC43

28.2

3.40

2.43

 

16.6

 

2.32

2.10

7.70

 

HC36

28.2

3.34

2.47

 

16.4

 

2.28

2.11

7.70

 

HC42

28.2

3.40

2.43

 

16.6

 

2.32

2.10

7.70

 

HD48

28.2

3.60

2.30

 

16.6

 

2.32

2.10

7.70

 

FC/MC/PC37

35.0

3.40

3.02

 

21.2

 

2.36

2.63

8.00

 

 

 

 

 

 

 

 

 

 

 

 

FC/MC/PC43

35.0

3.42

3.00

 

21.2

 

2.36

2.63

8.00

THGD36S41S1

 

 

 

 

 

 

 

 

 

 

FC/MC/PC48

35.0

3.42

3.00

 

21.4

 

2.36

2.66

8.00

 

HC42

35.0

3.42

3.00

 

21.2

 

2.36

2.63

8.00

 

HD48

35.0

3.40

3.02

 

20.0

 

2.16

2.71

8.00

 

FC/MC/PC48

41.0

3.48

3.45

 

28.0

 

2.46

3.34

8.00

 

FC/MC/PC60

41.0

3.66

3.28

 

27.8

 

2.56

3.18

8.00

THGD42S41S1

 

 

 

 

 

 

 

 

 

 

HC42

41.0

3.46

3.47

 

27.8

 

2.48

3.29

8.00

 

HC60

41.0

3.66

3.28

 

27.8

 

2.56

3.18

8.00

 

HD60

41.0

3.14

3.83

 

27.6

 

2.26

3.58

8.00

 

FC/MC/PC48

50.5

3.32

4.46

 

30.8

 

2.24

4.03

8.00

 

FC/MC/PC60

51.0

3.50

4.27

 

30.6

 

2.34

3.83

8.00

THGD48S41S1

 

 

 

 

 

 

 

 

 

 

HC60

51.0

3.50

4.27

 

30.6

 

2.34

3.83

8.00

 

HD60

50.0

2.98

4.92

 

30.6

 

2.06

4.35

8.00

 

MC62

50.5

3.38

4.38

 

30.6

 

2.28

3.93

8.00

THGD60S41S1

MC62

56.5

3.48

4.76

 

35.4

 

2.42

4.29

8.00

1.Rated CFM same as for cooling.

2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and

no supplemental electric heat operation.

CP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

— = Not Applicable.

12

Johnson Controls Unitary Products

Page 12
Image 12
York THGD18 THRU 60 warranty FC/MC/PC/UC1