York THGD18 THRU 60 warranty HEATING PERFORMANCE - With Air Handler Continued, YTG-B-0508

Models: THGD18 THRU 60

1 30
Download 30 pages 54.87 Kb
Page 11
Image 11

397763-YTG-B-0508

HEATING PERFORMANCE - With Air Handler (Continued)

UNIT

AIR

COIL1

 

 

ARI HEATING2

 

 

MODEL*

HANDLER

MODEL

 

47°F

 

 

17°F

 

HSPF

 

 

 

MBH

COP

KW

MBH

COP

KW

STD

 

13 SEER

HP WITH AV / SV / F*FV - VARIABLE SPEED

 

 

 

 

THGD18S41S1

AV24

16.8

3.62

1.36

11.5

3.18

1.06

8.00

THGD24S41S1

AV24

22.4

3.72

1.76

12.4

2.50

1.45

8.00

AV36

22.8

3.72

1.80

12.4

2.50

1.45

8.00

 

THGD30S41S1

AV36

27.6

3.64

2.22

16.0

2.50

1.88

8.00

THGD36S41S1

AV36

35.0

3.58

2.87

20.8

2.46

2.48

8.00

THGD42S41S1

AV/SV48

41.0

3.84

3.13

27.2

2.66

3.00

8.00

 

AV/SV48

50.5

3.62

4.09

30.0

2.42

3.63

8.00

THGD48S41S1

AV/SV60

50.5

3.62

4.09

30.2

2.40

3.69

8.00

 

F4FV060

50.5

3.62

4.09

30.2

2.40

3.69

8.00

 

 

13 SEER HP WITH AHP

/ SHP /

F*FP

 

 

 

 

 

THGD18S41S1

AHP18

17.0

3.38

1.47

8.2

2.16

1.11

7.70

F4FP24

17.0

3.34

1.49

12.5

3.04

1.21

7.70

 

THGD24S41S1

AHP30

23.2

3.40

2.00

12.6

2.24

1.65

7.70

F4FP030

23.2

3.40

2.00

12.6

2.24

1.65

7.70

 

THGD30S41S1

AHP36

28.2

3.40

2.43

16.6

2.32

2.10

7.70

F4FP040

28.0

3.32

2.47

16.4

2.28

2.11

7.70

 

THGD36S41S1

AHP36

35.0

3.40

3.02

21.0

2.40

2.56

8.00

F4FP045

35.0

3.40

3.02

21.6

2.42

2.62

8.00

 

 

AHP/SHP48

41.0

3.32

3.62

28.2

2.36

3.50

8.00

THGD42S41S1

 

 

 

 

 

 

 

 

 

F4FP045

41.0

3.68

3.27

27.8

2.56

3.18

8.00

 

F5FP048

41.0

3.68

3.27

27.6

2.58

3.14

8.00

 

AHP/SHP60

50.5

3.58

4.13

30.2

2.40

3.69

8.00

THGD48S41S1

 

 

 

 

 

 

 

 

 

F5FP048

50.5

3.46

4.28

30.6

2.32

3.87

8.00

 

F5FP060

50.5

3.60

4.11

30.2

2.40

3.69

8.00

1.Rated CFM same as for cooling.

2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.

CP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

— = Not Applicable.

Johnson Controls Unitary Products

11

Page 11
Image 11
York THGD18 THRU 60 HEATING PERFORMANCE - With Air Handler Continued, YTG-B-0508, Johnson Controls Unitary Products