HEATING CAPACITY - With Variable Speed Furnaces (Continued)

UNIT

VARIABLE

COIL1

 

 

ARI HEATING2

 

 

SPEED

 

 

 

 

 

 

 

MODEL

MODEL

 

47°F

 

 

17°F

 

HSPF

FURNACE

 

 

 

 

 

 

 

 

 

MBH

COP

KW

MBH

COP

KW

STD

 

 

 

 

PV8*C16

FC/MC/PC48C

50.0

3.28

4.47

30.6

2.24

4.00

8.00

 

PV8*C20

FC/MC/PC48C

50.5

3.34

4.43

30.6

2.26

3.97

8.00

 

P(C,V)9*C16

FC/MC/PC48C

50.5

3.32

4.46

30.8

2.24

4.03

8.00

 

P(C,V)9*C20

FC/MC/PC48C

50.5

3.34

4.43

30.6

2.26

3.97

8.00

 

P(C,V)9*D20

FC/MC/PC48D

50.0

3.38

4.34

30.6

2.28

3.93

8.00

 

PV8*C16

FC/MC/PC60C

50.5

3.50

4.23

30.4

2.34

3.81

8.00

 

PV8*C20

FC/MC/PC60C

50.5

3.56

4.16

30.4

2.38

3.74

8.00

 

P(C,V)9*C16

FC/MC/PC60C

51.0

3.52

4.25

30.6

2.34

3.83

8.00

 

P(C,V)9*C20

FC/MC/PC60C

50.5

3.54

4.18

30.4

2.36

3.78

8.00

THGD48S41S1

P(C,V)9*D20

FC/MC/PC60D

50.5

3.58

4.13

30.2

2.38

3.72

8.00

P(C,V)9*D20

HC60D

50.5

3.58

4.13

30.2

2.38

3.72

8.00

 

 

PV8*C16

HD60C

49.5

2.94

4.93

30.4

2.04

4.37

8.00

 

PV8*C20

HD60C

49.5

3.02

4.80

30.4

2.08

4.28

8.00

 

P(C,V)9*C16

HD60C

50.0

2.98

4.92

30.6

2.06

4.35

8.00

 

P(C,V)9*C20

HD60C

49.5

3.00

4.84

30.4

2.06

4.33

8.00

 

P(C,V)9*D20

HD60D

49.5

3.04

4.77

30.2

2.08

4.26

8.00

 

PV8*C20

MC62C

50.5

3.42

4.33

30.4

2.30

3.87

8.00

 

P(C,V)9*C16

MC62C

50.5

3.38

4.38

30.6

2.28

3.93

8.00

 

P(C,V)9*C20

MC62C

50.5

3.40

4.35

30.4

2.30

3.87

8.00

 

P(C,V)9*D20

MC62D

50.0

3.44

4.26

30.2

2.32

3.82

8.00

 

PV8*C20

MC62C

56.5

3.52

4.70

35.2

2.44

4.23

8.00

THGD60S41S1

 

 

 

 

 

 

 

 

 

P(C,V)9*C20

MC62C

56.5

3.44

4.81

35.2

2.42

4.26

8.00

 

P(C,V)9*D20

MC62D

56.0

3.46

4.74

35.0

2.42

4.24

8.00

1.Rated CFM same as for cooling.

2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.

3.Variable speed furnaces have B.O.D (Blower on Delay) standard.

CP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

— = Not Applicable.