Lamp replacement

Lamp replacement

When the lamp no longer functions, replace it with a new one.

Caution:

• Do not remove the lamp immediately after using the projector. You

may get burned because the lamp very hot after use.

• Before replacing the lamp, press the POWER button to turn off the

lamp and wait for two minutes for lamp to cool down. Unplug the

power cord from wall outlet and wait one hour for the lamp to cool

down completely.

9. Tighten up the screw (a) using a Phillips(a) screwdriver (+) to secure the lamp

cover.

Reset of the lamp operation time

Plug in the power cord, and reset the lamp operation time by keep pressing the W, X, and POWER buttons on the control panel at the same time about 5 seconds.

• Do not remove the lamp except for replacement. Careless han-

dling can cause injury or fire.

Important:

• Unless these three buttons are pressed

(b)

• Do not touch the lamp directly. It may break and cause injury or

burn.

• Be sure not to drop the lamp lid screw into the projector. Also be

sure not to put metal or any flammable objects inside because it

may cause fire or electric shock. If any objects should fall inside,

unplug and contact your dealer.

• Install the lamp securely to prevent failure and fire.

• If the lamp should break, small glass fragments may fall out

through the grilles and some may remain inside of the projector or

the lamp box. When taking the lamp box out, be sure to turn over

the projector and hold the handle of the lamp box to avoid injury

due to the glass fragments.

• If the lamp should break, never shake the lamp box or hold it in

front of your face after removing it. The lass fragments may fall out

and cause injury to your eyes.

• When placing the projector upside down to replace the lamp or

conduct maintenance, ensure that the projector is securely placed

before working with it.

• Be sure to use the lamp exclusive to this projector, VLT-XD206LP.

Use of other lamps may cause a failure of the projector.

1.Reverse the projector gently.

2.Loosen the screws (a) using a Phillips

 

screwdriver (+), and remove the lamp

 

 

cover (b).

 

3.

Loosen the screws (c) using a Phillips

 

 

screwdriver (+).

 

4.

Pull up the handle.

(a)

5.

Pull out the lamp box by the handle

 

while holding the projector.

• Pull the lamp box out of the projec- tor slowly. If it is pulled out quickly, the lamp may break scattering glass fragments.

• Do not spill liquid on the removed lamp box or do not place it near any flammable object or where children

 

can reach to prevent injury or fire.

(b)

 

 

6.

Load a new lamp box securely into the

(c)

 

projector in the right orientation.

 

7.

Put the handle back to the original posi-

 

 

tion.

 

 

• Make sure that the handle is

 

 

locked.

 

8.Tighten up the screws (c) using a Phil-

lips screwdriver (+).

at the same time, the lamp operation time isn’t reset.

• Make sure that the STATUS indicator is lit once (red) and the lamp operation time is reset successfully.

• The projector doesn’t turn on if the lamp cover isn’t attached securely.

• Be sure to reset the lamp operation time whenever you replace the lamp.

• Do not reset the lamp operation time unless you replace the lamp.

Caution:

The lamp is fragile. If it is broken, be careful not to cut yourself with glass fragments.

Contact your dealer for a new lamp.

The lamp in this product contains mercury. Please dispose of properly.

Interval of lamp replacement

When the lamp operation time exceeds the time elapsed*1, the POWER LED will light green and STATUS LED will blink red. In this case, replace the lamp immediately.

XD206U

*1 2850 Hours

*2 3000 Hours*3

The times above are when LAMP MODE of the INSTALLATION menu is set to LOW. When it is set to STANDARD, this duration will be short- ened.

*3 When LAMP MODE is set to STANDARD, the time elapsed until the lamp shutdown will be shortened to 2000 hours.

Caution:

This projector uses a lamp that contains mercury. Disposal of the lamp or the projector with the lamp may be regulated due to envi- ronmental considerations. For disposal or recycling information, please contact your local authorities or the Electronic Industries Alliance: www.eiae.org. (For US only).

EN-22