invision Serial/Modem Charging Cradle User Guide

Symptom: Attempt by the cradle to HotSync the terminal through the modem failed.

Possible Cause

Action

The terminal was removed from the

Place the terminal back in the cradle to allow the

cradle while the HotSync was in

cradle to make another HotSync attempt.

progress.

 

 

 

Terminal or cradle was disconnected from

Unplug the modem cable for 30 seconds to allow

the telephone line while the HotSync was

the local telephone connection to hang up. Be

in progress.

sure to close any open windows on the terminal

 

and any modem connections.

 

 

Terminal’s battery is dead.

Wait for two (2) minutes before trying a HotSync

 

again to allow the battery to recharge.

 

 

Active Error dialog box on terminal.

The Error dialog box on the terminal must be

 

cleared. Use the stylus to press “OK” on the

 

terminal’s touchscreen.

 

 

Modem or telephone lines being operated

Modify init string in US/Canada to “AT&F\N5”

in an electrically noisy environment.

forcing MNP error correction, or

 

“AT&F+MS=V32B” forcing B32bis (14,400 bps)

 

connection.

 

For International operation use

 

“AT&F\N5;+GCI=xx;” forcing MNP error

 

correction or “AT&F+MS=V32B;+GCI=xx;”

 

forcing V32bis (14,400 bps) connection.

 

 

Mobility Electronics, Inc

8

 

 

Page 11
Image 11
Mobility Electronics PS6S1800M manual Invision Serial/Modem Charging Cradle User Guide