Monessen Hearth 624WBPF Chimney Offset Installation, Chimney Requirements - Offset Installations

Models: 624WBPF

1 32
Download 32 pages 53.68 Kb
Page 15
Image 15
CHIMNEY OFFSET INSTALLATION

CHIMNEY OFFSET INSTALLATION

624WBPF Woodburning Fireplace

 

 

 

Chimney Requirements - Offset Installations

Chimney Flue Exit

 

 

 

Chimney

 

 

 

 

 

Section

 

 

 

 

 

Elbow

 

30°

 

 

 

 

 

 

 

 

 

B

 

 

Return

A

 

 

G

 

Elbow

 

 

 

 

 

 

 

 

 

 

 

G

 

D

 

 

 

30°

 

 

E

 

 

Offset

 

 

 

Rise

 

Elbow

 

 

 

6 FT.

 

 

 

 

 

 

 

 

11CS Sup-

 

C

 

 

 

 

 

 

 

 

30°

port

 

 

 

 

 

 

 

 

Offset

 

H

Return

 

 

 

 

Elbow

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

B

 

 

 

30°

 

 

 

 

 

Offset

 

 

 

 

 

 

Elbow

 

 

 

Hearth Floor

 

 

 

 

Example 1

 

 

Example 2

 

Example 3

Notes: G + H cannot exceed 20 feet.

 

 

FP269

*11CF Chimney airspace clearance = 2" minimum.

 

 

Offset

Rise

 

 

 

 

 

 

 

FP282

 

30° Elbow Offsets

 

 

 

 

 

 

 

 

1' 1¹⁄₂'

3'

4'

 

Offset

Rise

 

 

 

 

Chimney Support

 

 

 

0

0

0

0

0

3"

11"

 

1

0

0

0

0

8¹⁄"

20"

 

0

1

0

0

0

11¹⁄" 25¹⁄"

 

2

0

0

0

0

13¹⁄" 29¹⁄"

 

1

1

0

0

0

16¹⁄" 34¹⁄"

 

0

0

1

0

0

20¹⁄" 40³⁄"

 

2

1

0

0

0

21³⁄" 43¹⁄"

 

0

0

0

1

0

26¹⁄" 51¹⁄"

 

0

1

1

0

0

28¹⁄" 55¹⁄"

 

1

0

0

1

0

31¹⁄" 60¹⁄

 

0

1

0

1

0

34¹⁄" 65¹⁄"

 

0

0

2

0

0

37¹⁄" 70³⁄"

 

1

1

0

1

1

41¹⁄" 77³⁄"

 

0

0

1

1

1

45" 83³⁄"

 

0

1

2

0

1

47¹⁄" 87¹⁄"

 

0

0

0

2

1

51"

94"

0

1

1

1

1

53¹⁄"

98"

Illustration Key

The following safety rules apply to offset installations (letters correspond with illustra- tion above):

A. Height of the chimney is measured from the hearth to the chimney exit.

 

 

624WBPF

Max.:

86’0”

Min.:

 

0

Elbows

14’0"

2

Elbows*

14’0”

4

Elbows*

21'0"

B. Do not use more than 4 elbows per chim- ney.

Attach the straps of the return (top) elbow to a structural framing member.

The offset (first) elbow of any pair does not have straps.

C. The chimney cannot be more than 30° from the vertical plane in any instal- lation.

D. The maximum length of the angled run of the total chimney system is 20 feet. (G plus H cannot exceed 20 feet.)

E. A chimney support (Model 11CS) is required every 6 feet of angled run of chimney. Chimney supports are required for every 30 feet and 60 feet chimney height above the hearth.

Determine the offset distance of your chimney arrangement from the center- line of the fireplace to the centerline of the chimney where it is to pass through the first ceiling.

NOTE: This offset distance may not be your full offset distance. See Examples 2 and 3.

0

0

3

0

1

56¹⁄" 103¹⁄"

0

1

0

2

1

59¹⁄" 108¹⁄"

0

0

2

1

1

62¹⁄" 113¹⁄"

0

1

3

0

1

64¹⁄" 117¹⁄"

0

0

1

2

1

68¹⁄"

124"

0

1

2

1

1

70¹⁄"

128"

0

0

0

3

1

74¹⁄" 134¹⁄"

0

1

1

2

2

78" 140³⁄"

0

0

3

1

2

81"

146"

0

1

0

3

2

84" 151¹⁄"

0

0

2

2

2

87" 156¹⁄"

0

1

3

1

2

89¹⁄" 160¹⁄"

0

0

1

3

2

93" 166³⁄"

0

1

2

2

2

95¹⁄" 170³⁄"

0

0

0

4

2

99¹⁄" 177³⁄"

0

1

1

3

2

101¹⁄" 181³⁄"

0

0

3

2

2

104¹⁄" 186¹⁄"

0

1

0

4

2

107¹⁄" 191¹⁄"

0

0

2

3

2

110¹⁄" 196³⁄"

0

1

3

2

3

114"

203¹⁄"

Figure 17

0

0

1

4

3

117³⁄"

209³⁄"

0

1

2

3

3

120"

213¹⁄"

0

0

0

5

3

123³⁄"

220"

53D9052

15

Page 15
Image 15
Monessen Hearth 624WBPF Chimney Offset Installation, Chimney Requirements - Offset Installations, Elbow Offsets, 53D9052