624WBPF Woodburning Fireplace | INSTALLATION PREPARATION |
|
|
Survey the planned location for the fireplace for overhead plumbing or electrical wires, etc., that might complicate the installation or endanger persons installing or cleaning the chimney. Avoid a location where the chimney cap will be near abrupt changes in the roof shape, nearby wall or embankments, under or near trees or above the roof of a single story wing of a two story building. Figure 6. All these conditions can cause turbulence or pressure conditions that can cause poor chimney draft and smoke spillage from the fireplace opening. Elbows may be used to offset the chimney to avoid obstructions or to locate the chimney cap in a preferred location. Refer to the sections of this manual pertaining to chimney offsets for instructions on proper elbow usage. Poor installation or location of the chimney cap and/or components can cause wind blown rain to enter the chimney.
If the fireplace is to be installed on an outside wall, the surrounding walls (chase) should be insu- lated. Failure to insulate the fireplace from outside temperatures will cause heat loss through and around the fireplace.
Single Story Installation with Attic Space
Chimney Cap
Multiple Story Installation
| Flue Outlet Height | |
Storm Collar | 3’ Min. or 2’ Above | |
any Point within 10’ | ||
| ||
Flashing |
| |
| Attic Space | |
| See Table | |
| 1 for Roof |
Chimney Cap
Storm Collar (Included with cap)
Flashing
Flue Outlet Height
3 ft. Min.
Attic Space
Opening Size |
14’ Min. |
Firestop Spacer |
Refer to Table 1 for Roof Opening Size
17” Square | (1Z\x” Air space | |
Clearance to | ||
Opening in | ||
Combustibles) | ||
Joist | ||
Chimney | ||
| ||
| Sections | |
| 2” Min. Air Space | |
| Clearance Between | |
| Combustibles and | |
| Chimney | |
| FP2347 | |
Figure 4 |
| |
| Preferred | |
| Location | |
| Poor | |
| Location |
17” Square Open- ing in Joist
Max. Instal-
lation Height
-
86 ft.
Support Re- quired Every
35 ft. 17” Square Opening in Joist
17” Square Opening in Joist
Firestop
Spacer (2”
Air Space Third Floor
Clearance to
Combustibles) Area
2” Clearance to Combustibles (Min.)
Firestop | Second | |
Floor Area | ||
Spacer |
Firestop
Spacer
First Floor
Area
Figure 5 | FP2348 |
Figure 6
FP1882