CLEARANCES | 624WBPF Woodburning Fireplace | |
|
|
|
Figure 3
Residential Installation
Chimney Cap
Roof Flashing
Firestop
11CF1 (1 ft. pipe) 11CF18 (1Z\x ft. pipe) 11CF3 (3 ft. pipe) 11CF4 (4 ft. pipe) Maintain 2” Minimum Air Space Between Chimney and Combustibles
1/2” Min. Air Space to Combustibles
Flexible Duct
Type
Combustion Air
Assembly (Optional)
FP2345
(Flue Outlet Height)
Storm Collar
14 ft. = Min. Height (No offsets)
14 ft. = Min. Height (2 30° Elbows)
21 ft. = Min. Height (4 30° Elbows)
86 ft. = Max. Height (Chimney support every 35 ft.)
Firestop
(Requires 17 x 17 framing)
(Floor Line)
Metal Safety Strip
Nail to Framing Mem-
Gas Line bers Each Side (Optional)
| NOTE | Combustible materials should not be installed below |
| top spacer. Noncombustible materials such as brick | |
| or tile may be used to trim face or the fireplace, com- | |
| bustibles must not overlap the black painted face of | |
|
| fireplace more than 1/8”. |
|
|
|
53D9052