![](/images/new-backgrounds/1025325/2532519x1.webp)
CLEARANCES
CLEARANCES TO COMBUSTIBLES
WARNING
Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
71"Minimum
12"
Maximum
Depth
11"Minimum
Minimum 4"
From Both
Side Walls
Figure 6 - Clearances
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.
10 | 54D0700 |