Monessen Hearth BDV600 Checking GAS Pressure and Electrical Installation, Electrical Wiring

Models: BDV400 BDV500 BDV300 BDV600

1 52
Download 52 pages 34.58 Kb
Page 28
Image 28

CHECKING GAS PRESSURE AND ELECTRICAL INSTALLATION

1.Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately.

2.To ease installation, a 30" (mm) flex line with manual shut-off valve has been provided with on this appliance. Install and attach 1/2" gas line onto shut-off valve.

3.After completing gas line connection, purge air from gas line and test all gas joints from the gas meter to the fireplace for leaks. Use a solution of 50/40 water and soap or a gas sniffer.

4.To adjust flame height, turn HI/LO knob to HI to get maximum pressure to burner. Turn HI/LO knob to LO to get minimum pressure.

5.To check gas pressures at valve, turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point. Turn unit to high. See Figure 35. After taking pressure reading, be sure and turn captured screw clockwise firmly to reseal. Do not over torque. Check test points for gas leaks.

ELECTRICAL WIRING

Pressure

Test “IN”

Pressure

Test “OUT”

HI/LO

Knob Pilot Adjustment

Screw

Figure 35 - Gas Pressure Check at Gas Valve

WARNING

Do not use open flame to check for

 

 

gas leaks.

 

 

This fireplace will work without any electrical supply. Electricity is only needed to operate blower.

NOTE: If installed in mobile home, fireplace must be bolted securely to floor.

CAUTION WARNING

Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city, and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/ NFPA 70 (latest edition) and Canadian Electrical Code, CSA C22.1.

Label all wires before disconnecting when servicing controls. Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing.

28

54D0700

Page 28
Image 28
Monessen Hearth BDV600, BDV500, BDV300 Checking GAS Pressure and Electrical Installation, Electrical Wiring, Gas leaks